Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
Physical Address
304 North Cardinal St.
Dorchester Center, MA 02124
🧪 DD CEN ISO TS is the prefix under which BSI publishes joint CEN/ISO Technical Specifications (CEN ISO/TS) as Drafts for Development (DD). A CEN ISO/TS is a “one-text” document developed at the technical level by CEN and ISO: ISO publishes it as an ISO/TS and CEN approves it as a CEN/TS, and BSI then implements it in the UK as DD CEN ISO/TS. These documents are provisional technical specifications, normally reviewed on a two-to-three-year cycle by the responsible BSI committee (e.g. TDW/4, EPL/278, PRI/88/2, B/526/3, PSE/17) which decides whether to promote them to formal standards. This batch collects 16 DD CEN ISO/TS documents covering geometrical product specification (GPS), electronic fee collection (EFC), plastics piping systems for hot and cold water, geotechnical investigation and testing, hazardous substances in footwear, uncertainty in hydrometry, fire-damper testing for the oil & gas industry, and sector-specific quality management systems.
All 16 documents in this batch are single-file series. Several are “Part 7” documents of multi-part plastics-piping series (the conformity-assessment guidance for 15874/15875/15876/15877/21003/22391), while others carry standalone numbers (e.g. 16181, 25377, 27469, 29001). The table below lists the complete inventory and subjects.
| Standard | Subject | ICS | Key Technical Content |
|---|---|---|---|
| DD CEN ISO/TS 14253-4:2010 | GPS — Inspection by measurement of workpieces and measuring equipment — Part 4: Background on functional limits and specification limits in decision rules | 17.040.01 | Background of GPS decision rules (functional/specification limits) |
| DD CEN ISO/TS 14907-2:2011 | Electronic fee collection — Test procedures for user and fixed equipment — Part 2: Conformance test for the onboard unit application interface | 35.240.60; 43.040.15 | OBU application-interface conformance tests |
| DD CEN ISO/TS 15874-7:2003 | Plastics piping systems for hot and cold water — Polypropylene (PP) — Part 7: Guidance for the assessment of conformity | 23.040.01; 91.140.60 | Conformity-assessment guidance for PP systems |
| DD CEN ISO/TS 15875-7:2003 | Plastics piping systems for hot and cold water — Crosslinked polyethylene (PE-X) — Part 7: Guidance for the assessment of conformity | 23.040.20; 91.140.60 | Conformity-assessment guidance for PE-X systems |
| DD CEN ISO/TS 15876-7:2003 | Plastics piping systems for hot and cold water — Polybutene (PB) — Part 7: Guidance for the assessment of conformity | 23.040.01; 91.140.60 | Conformity-assessment guidance for PB systems |
| DD CEN ISO/TS 15877-7:2009 | Plastics piping systems for hot and cold water — Chlorinated poly(vinyl chloride) (PVC-C) — Part 7: Guidance for the assessment of conformity | 23.040.01; 23.040.20; 91.140.60 | Conformity-assessment guidance for PVC-C (2009 supersedes 2003) |
| DD CEN ISO/TS 16181:2011 | Footwear — Critical substances potentially present in footwear and footwear components — Determination of phthalates in footwear materials | 61.060 | Determination of phthalates in footwear materials |
| DD CEN ISO/TS 16407-1:2011 | Electronic fee collection — Evaluation of equipment for conformity to ISO/TS 17575-1 — Part 1: Test suite structure and test purposes | 03.220.20; 35.240.60 | EFC front-end equipment conformance testing (Part 1) |
| DD CEN ISO/TS 16410-1:2011 | Electronic fee collection — Evaluation of equipment for conformity to ISO/TS 17575-3 — Part 1: Test suite structure and test purposes | 03.220.20; 35.240.60 | EFC context-data conformance testing (Part 1) |
| DD CEN ISO/TS 17892-6:2004 | Geotechnical investigation and testing — Laboratory testing of soil — Part 6: Fall cone test | 13.080.20; 93.020 | Fall cone test (liquid/plastic limits) for soils |
| DD CEN ISO/TS 21003-7:2008+A1:2010 | Multilayer piping systems for hot and cold water installations inside buildings — Part 7: Guidance for the assessment of conformity | 23.040.20; 91.140.60 | Conformity-assessment guidance for multilayer systems |
| DD CEN ISO/TS 22391-7:2011 | Plastics piping systems for hot and cold water — Polyethylene of raised temperature resistance (PE-RT) — Part 7: Guidance for the assessment of conformity | 23.040.01; 91.140.60; 93.025 | Conformity-assessment guidance for PE-RT systems |
| DD CEN ISO/TS 22476-11:2005 | Geotechnical investigation and testing — Field testing — Part 11: Flat dilatometer test | 93.020 | Flat dilatometer test (DMT) method and evaluation |
| DD CEN ISO/TS 25377:2007 | Guidance on uncertainty in hydrometry | 17.120.20 | Uncertainty evaluation for flow/level hydrometric measurements |
| DD CEN ISO/TS 27469:2011 | Petroleum, petrochemical and natural gas industries — Test method for fire dampers | 75.180.10 | Performance test method for fire dampers (supersedes DD ISO/TS 27469) |
| DD CEN ISO/TS 29001:2011 | Petroleum, petrochemical and natural gas industries — Sector-specific quality management systems — Requirements for product and service supply organizations | — | Oil & gas sector QMS requirements (ISO/TS 29001:2010) |
The most systematic group in this batch is the series of “Part 7: Guidance for the assessment of conformity” for plastics piping systems for hot and cold water installations, covering six pipe-material systems: polypropylene (PP), crosslinked polyethylene (PE-X), polybutene (PB), chlorinated PVC (PVC-C), multilayer piping systems, and polyethylene of raised temperature resistance (PE-RT). Each part works with the main body of the corresponding series (Parts 1–5: general, pipes, fittings, systems, recommended installations) and specifies the conformity-assessment elements for manufacturers — initial type testing (ITT), factory production control (FPC), product sampling and certification (e.g. third-party certification) — providing the basis for CE marking and market access of building water-supply piping.
The UK national foreword of 21003-7 notably warns that UK cold-water supply pressure can be up to 12.5 bar, which not all application classes satisfy; UK practice relies mainly on push-fit connections, which the standard describes only generically as “mechanical fittings”; and the failure temperature of 100 °C shown in the Part 1 Tables differs from the 110 °C UK boiler condition, so BS 7291-1 should be consulted. This illustrates that adopting an international technical specification always requires a suitability assessment against national engineering practice.
DD CEN ISO/TS 29001:2011 is identical to ISO/TS 29001:2010 and supersedes DD ISO/TS 29001:2010. It defines sector-specific quality management system (QMS) requirements for the petroleum, petrochemical and natural gas industries, adding to ISO 9001 industry-specific requirements for design and development, purchasing, product traceability, inspection and testing, and control of nonconforming product, applicable to organisations supplying products and services to the sector. The Technical Specification has since been developed into the formal international standard ISO 29001:2020, whose 2020 edition is fully aligned with the high-level structure of ISO 9001:2015.
For manufacturers and contractors supplying the oil & gas industry, ISO/TS 29001 (now ISO 29001) is a common qualification for tendering and supply-chain access; its core value is translating the demanding quality, safety and traceability expectations of oil & gas projects into auditable management-system clauses.
DD CEN ISO/TS 27469:2011 specifies the test methods for fire dampers in the petroleum, petrochemical and natural gas industries, superseding DD ISO/TS 27469. Fire dampers shut off airflow in ventilation duct systems on fire to prevent the spread of flames and smoke; their closing reliability under high temperature is a core element of fire safety in petrochemical plants. The standard defines the test apparatus, specimen preparation, test procedure and result evaluation for the operational performance, leakage and structural integrity of dampers under fire conditions.
The document echoes the international harmonisation efforts of ISO/API in the field of fire dampers. In fire and petrochemical piping projects, selected fire dampers should be type-tested against this standard (or its later formal successor) and documented.
The electronic fee collection (EFC) family appears in this batch as three documents: DD CEN ISO/TS 14907-2:2011 specifies conformance tests for the onboard unit (OBU) application interface; DD CEN ISO/TS 16407-1:2011 and DD CEN ISO/TS 16410-1:2011 give the evaluation of equipment for conformity to ISO/TS 17575-1 (front-end systems) and ISO/TS 17575-3 (context data) respectively, with “test suite structure and test purposes (TSS&TP)”. Together they form the conformance-verification framework of the EFC system — from the onboard unit to roadside equipment, and from the application interface to charging context — ensuring interoperability of equipment from different suppliers across different tolling systems.
The EFC standard family (ISO 17575/14906/16407/16410 etc.) underpins the construction of ETC and free-flow tolling systems in Europe and worldwide. The Test Suite Structure (TSS) defines the test organisation hierarchy, and the Test Purposes (TP) tables list each requirement to be verified with its Abstract Test Suite (ATS) numbers, forming the basis for conformance certificates issued by accredited laboratories.
DD CEN ISO/TS 17892-6:2004 specifies the fall cone test in laboratory testing of soils, used to determine the liquid limit (and, in some systems, the plastic limit) of fine-grained soils, complementing or replacing the Casagrande cup method; DD CEN ISO/TS 22476-11:2005 specifies the flat dilatometer test (DMT) in field testing, deriving horizontal stress and deformation parameters of the ground. The two form complementary “laboratory + field” means of obtaining soil parameters for geotechnical investigation and foundation design.
DD CEN ISO/TS 25377:2007 provides guidance on the uncertainty of hydrometric measurements (discharge, water level, etc.), applying measurement-uncertainty evaluation (the GUM approach) to hydrological gauging so that gauging stations and water authorities can quantify the reliability of discharge derivation. It is the responsibility of BSI committee CPI/113 (Hydrometry).