📡 BS ISO/IEC 18047 is the British Standards Institution (BSI) adoption of the ISO/IEC 18047 series, covering conformance test methods for radio frequency identification (RFID) devices. The series defines conformance test methods for each air-interface protocol specified in ISO/IEC 18000, used to verify whether an RFID tag (transponder) and reader conform to the requirements of the corresponding air-interface standard. It was prepared by UK technical committee IST/34 (Automatic identification and data capture techniques) and carries ICS classification 35.040. The two standards in this series cover the low-frequency air interface below 135 kHz (Part 2) and the ultra-high-frequency air interface at 860–960 MHz (Part 6).
The ISO/IEC 18000 series defines several RFID air-interface protocols covering different operating bands (e.g., below 135 kHz, 13.56 MHz, 433 MHz, 860–960 MHz, 2.45 GHz). The ISO/IEC 18047 series provides conformance test methods for each air interface, specifying test items, test setup, default conditions, and pass/fail criteria.
The two parts currently in the BS ISO/IEC 18047 series are shown below. Together they cover two of the most representative bands — low frequency and ultra-high frequency — and are important references for RFID device certification and interoperability verification.
| Standard | Subject | Corresponding Air Interface | Key Content |
|---|---|---|---|
| BS ISO/IEC 18047-2:2012 | Test methods for air-interface communications below 135 kHz | ISO/IEC 18000-2 (low frequency, LF) | Test conditions, default conditions, test setup, and conformance criteria |
| BS ISO/IEC 18047-6:2012 | Test methods for air-interface communications at 860 MHz to 960 MHz | ISO/IEC 18000-6 (ultra-high frequency, UHF) | Test equipment setup, default test conditions, and conformance test methods |
Both standards follow a common structural framework, including:
For example, BS ISO/IEC 18047-6 explicitly specifies the “setup of test equipment” and the “default conditions applicable to the test methods”, ensuring that results from different laboratories are comparable and repeatable.
BS ISO/IEC 18047-2 specifies a number of conformance tests for the below-135 kHz low-frequency air interface (corresponding to ISO/IEC 18000-2), covering signal parameters between tag and reader, modulation, coding, timing, and protocol interaction. Low-frequency RFID is commonly used for access control, animal ear tags, and industrial near-field identification; the test focus is on magnetic coupling characteristics and communication timing.
BS ISO/IEC 18047-6 specifies more complex test methods for the 860–960 MHz ultra-high-frequency air interface (corresponding to ISO/IEC 18000-6), including reader transmit parameters, tag backscatter modulation, protocol timing, anti-collision, and command/response behaviour. UHF RFID is used for logistics, retail, and asset management; the test focus is on the backscatter link and multi-tag anti-collision performance.
RFID conformance testing plays an important role in device certification, tendering, and incoming inspection. Engineering practice points include: