BS EN ISO 25745 — Energy Performance of Lifts, Escalators and Moving Walks

Energy Performance of Lifts, Escalators and Moving Walks

🏢 The BS EN ISO 25745 series specifies methods for measuring, calculating and classifying the energy performance of lifts, escalators and moving walks, making it an important standard for energy-efficiency evaluation and management of building vertical transportation systems. Published by BSI as the UK implementation of EN ISO 25745, the technical content is identical to ISO 25745 and was prepared by ISO/TC 178 (Lifts, escalators and moving walks) in collaboration with CEN/TC 10 (Lifts, escalators and moving walks), with UK participation entrusted to Technical Committee MHE/4 (Lifts, hoists and escalators). The series comprises three parts.

💡 In public and high-rise buildings, vertical transportation (lifts, escalators) can account for about 5–10% of total building energy consumption. Measuring and classifying lift and escalator energy supports design selection, retrofit and operational management, contributing to overall building energy goals.

1. Series Structure and Scope 📌

The series consists of three parts:

StandardYearTitleContent
BS EN ISO 25745-12012Energy measurement and verificationEnergy measurement methods for lifts, escalators and moving walks.
BS EN ISO 25745-22015Energy calculation and classification for liftsLift energy calculation and efficiency classification.
BS EN ISO 25745-32015Energy calculation and classification of escalators and moving walksEscalator and moving walk energy calculation and classification.

All parts fall under ICS 91.140.90 (Lifts, escalators). Part 1 provides a unified energy measurement method; Parts 2 and 3 provide energy calculation models and classification systems for lifts and escalators/moving walks respectively, together forming a complete energy-efficiency evaluation framework.

⚠️ Energy classification is based on standardized measurement and calculation conditions, reflecting the intrinsic efficiency of the equipment. Actual operating consumption is also affected by building traffic, control strategy and usage patterns, so it should be combined with operational statistics for energy management.

2. Energy Measurement and Verification (Part 1) ⚡

Part 1 (BS EN ISO 25745-1:2012) specifies energy measurement methods for lifts, escalators and moving walks, covering measuring instruments, measurement conditions, measurement procedures and expression of results. It defines energy consumption measurement under different operating modes (e.g., running, standby, shut-down) and combinations of load conditions (empty, full, rated load).

By measuring energy consumption in each mode per the standard procedure, baseline data suitable for comparison and classification are obtained, providing input for the calculation and classification in Parts 2 and 3.

3. Lift Energy Calculation and Classification (Part 2) 🏗️

Part 2 (BS EN ISO 25745-2:2015) provides lift energy calculation and efficiency classification methods. This part establishes an energy consumption calculation model, dividing lift energy into running, standby and shut-down components, and considering counterweight ratio, travel height, rated load and number of journeys.

Based on the calculation, lifts can be classified into efficiency classes (e.g., an A~G framework), facilitating comparison of different lift products’ efficiency in building projects, selection of energy-saving options and assessment of retrofit benefits.

4. Escalator and Moving Walk Energy Calculation and Classification (Part 3) 🪜

Part 3 (BS EN ISO 25745-3:2015) provides energy calculation and classification methods for escalators and moving walks. Escalator operating characteristics differ from lifts; their energy consumption mainly depends on operating speed, load flow and start/stop strategy (e.g., variable frequency drive and motion-sensor start). This part establishes the corresponding energy calculation model and provides classification methods.

Combined with escalator energy-saving technologies (e.g., variable frequency, full-load motion-sensor start/stop), this part provides a quantitative basis for escalator energy management in commercial and public transport buildings.

5. Engineering Practice Applications 🛠️

  • 🏬 Building design: Lift and escalator efficiency classification as a device-selection indicator.
  • 💰 Energy retrofit: Assessing the benefits of variable-frequency conversion, standby-mode optimization and other measures.
  • 📊 Operational management: Optimizing operating strategies based on measurement data to reduce actual consumption.
  • 🌱 Green buildings: Supporting vertical transportation energy requirements in LEED, BREEAM and national green-building schemes.
✅ Using standardized energy measurement and classification methods enables objective efficiency comparison of lifts and escalators; combined with variable-frequency drives, group control scheduling and standby energy saving, significant energy reductions can be achieved, supporting building decarbonization.

6. Frequently Asked Questions ❓

❓ Q: What is the relationship between Part 1 and Parts 2 and 3?
A: Part 1 provides a unified energy measurement method; Parts 2 and 3 perform energy calculation and classification based on measurement data (or product parameters). They are used together.
❓ Q: How is the lift efficiency class determined?
A: Calculate the unit-transport or comprehensive energy index using the Part 2 model, then determine the class against the classification table, with class boundaries given in the standard.
❓ Q: Why is standby energy important?
A: Lifts spend most of their time in standby; standby energy (lighting, control, cooling) can be a significant share of total consumption, so optimizing standby strategy is an effective saving measure.
❓ Q: Does the standard apply to retrofit projects?
A: Yes. By measuring energy before and after retrofit and comparing against classes, the energy savings of measures such as variable-frequency conversion and group-control optimization can be quantified.
🔒
正在加载下载地址,请稍候 10 秒

Leave a Reply

Your email address will not be published. Required fields are marked *