📏 BS EN ISO 18674 is the British Standard series on geotechnical monitoring by field instrumentation, classified under ICS 13.080.20 (Physical properties of soils) and 93.020 (Earthworks, excavations, foundation construction). During construction and operation of deep excavations, tunnels, slopes, dams, and underground works, ground displacements and the stress state of support structures must be continuously monitored by field instruments to ensure project safety and validate design assumptions. The series provides unified technical rules for planning, instrument selection, installation, data acquisition, data processing, and reporting of field monitoring, supporting the observational method in geotechnical design and information-based construction.
💡 Geotechnical monitoring by field instrumentation is the core of the “observational method” design and information-based construction: measured data are used to adjust design and construction schemes in time and to prevent engineering risks.
1. Scope and General Framework 📌
The series was prepared by ISO/TC 182 (Geotechnics) in collaboration with CEN/TC 341 (Geotechnical Investigation and Testing), with UK participation through Technical Committee B/526/3 (Site investigation and ground testing). The series is planned to be published in parts by monitored object, with the following two parts currently available:
| Standard Part | Year | Subject | Primary Monitored Object |
| BS EN ISO 18674-1 | 2015 | General rules | General requirements for planning, instruments, data, and reporting of field monitoring |
| BS EN ISO 18674-2 | 2016 | Measurement of displacements along a line: Extensometers | Displacement measurement in boreholes or along a measurement line |
⚠️ The success of field monitoring depends not only on the instruments themselves but also on monitoring point layout, installation quality, and data interpretation. The standard stresses monitoring planning first: define monitoring objectives, alarm values, and emergency measures before selecting instruments and laying out monitoring points.
2. Series Structure and Technical Points 🔬
2.1 Part 1 General Rules (BS EN ISO 18674-1:2015)
Part 1 specifies the general rules for geotechnical monitoring by field instrumentation, including: definition of monitoring objectives and scope of application, planning and design of the monitoring scheme, instrument performance requirements and selection principles, layout of monitoring sections, measurement frequency, data acquisition and recording, data processing and presentation of results, and requirements for preparing the monitoring report. The part also clarifies the role and division of responsibility of monitoring in each stage of geotechnical investigation, design, and construction, providing a unified methodology for the entire monitoring activity.
2.2 Part 2 Extensometers (BS EN ISO 18674-2:2016)
Part 2 specifically addresses extensometers, specifying requirements for measuring displacements along a line. It covers: types of extensometers (rod, vibrating-wire, magnetic-ring, fibre-optic, etc.) and their working principles, layout of anchor points and installation procedure, instrument calibration and accuracy requirements, data acquisition systems, and processing and presentation of measurement results. Extensometers measure the relative displacement between two anchor points in a borehole or within the ground, and are widely used for monitoring dam, tunnel surrounding rock deformation, deep slope displacement, and excavation bottom heave.
💡 The quality of anchoring and installation is the key to successful extensometer measurement: anchor points must be firmly bonded to the monitored stratum, and borehole backfill and grouting should ensure the instrument deforms together with the ground, avoiding false readings where “the instrument measures displacement but the ground does not move it”.
3. Key Technical Requirements 🔧
The series sets out the following key technical requirements for field monitoring:
- Clear monitoring objectives: monitoring should serve a defined risk-control objective; the monitored items, accuracy, and frequency should match the engineering risk level.
- Instrument performance: range, resolution, accuracy, and long-term stability should meet monitoring needs, and instruments should be calibrated as required.
- Installation procedure: instruments should be installed following a standardised procedure, ensuring they deform together with the ground or structure, with initial readings taken promptly after installation.
- Data management: establish mechanisms for data acquisition, transmission, storage, and backup, using a unified data format and reference for historical comparison.
- Alarm and warning: set alarm and warning values based on design documents; when monitoring data exceed limits, follow emergency procedures.
🚨 Field monitoring data are the “barometer” of engineering safety. When displacement rate or cumulative displacement exceeds the alarm value, immediately stop hazardous work, convene a review, and take reinforcement or emergency measures — never ignore anomalous data.
4. Engineering Practice and Application Guidance 🛠️
- 🔍 Deep excavation monitoring: during excavation, monitor the horizontal displacement of the retaining structure, ground settlement, and support axial force, and judge stability using extensometer and inclinometer data together.
- 🔧 Tunnels and underground works: use multi-point extensometers to monitor surrounding rock convergence and loosening zone development, guiding support timing and parameter adjustment.
- 📊 Slope and dam monitoring: through deep displacement and seepage pressure monitoring, identify slip surfaces and seepage anomalies early to prevent landslide and dam instability risks.
- 📋 Information-based construction: establish a linkage mechanism between monitoring data and design/construction, using measured results to revise calculation models and construction schemes.
5. Frequently Asked Questions ❓
❓ Q: What is an extensometer used for?
A: An extensometer measures the relative displacement between two anchor points in a borehole or within the ground (i.e., the change in distance between two points). It is an important instrument for monitoring deep ground deformation, commonly used in dams, tunnels, and slopes.
❓ Q: Why is Part 1 General Rules important?
A: Part 1 provides the methodological framework for the entire field monitoring activity, covering planning, instruments, data, and reporting requirements, and is the common basis for monitoring carried out with other parts (e.g., extensometers, inclinometers).
❓ Q: What should be done when monitoring data show anomalies?
A: First verify the authenticity of the data (ruling out instrument failure and recording errors), then compare with alarm values; if the exceedance is confirmed, convene a review per the emergency plan and take appropriate engineering measures.
❓ Q: Do field instruments need periodic calibration?
A: Yes. Instruments should be calibrated per the standard before installation and checked at specified intervals during use to avoid drift that distorts monitoring data.