BS EN ISO 17769 — Liquid Pumps and Installation General Terms, Definitions, Quantities, Letter Symbols and Units (Pumps and Pumping System)

Liquid Pumps and Installation — General Terms, Definitions, Quantities, Letter Symbols and Units — Part 1: Liquid Pumps; Part 2: Pumping System (2012 Editions)

⚙️ BS EN ISO 17769 specifies general terms, definitions, quantities, letter symbols, and units for liquid pumps and pumping systems, and is the foundational standard for terminology unification and data exchange in the pump field. The series consists of two parts: Part 1 covers liquid pumps, while Part 2 covers pumping systems. The UK standards BS EN ISO 17769-1:2012 and BS EN ISO 17769-2:2012 are identical implementations of EN ISO 17769-1:2012 and EN ISO 17769-2:2012, prepared by BSI Technical Committee MCE/6 (Pumps and pump testing); Part 1 replaces the withdrawn BS EN 12723:2000.

In pump design, selection, testing, and operation, the definitions and symbols of parameters such as flow rate, head, efficiency, net positive suction head (NPSH), and shaft power must be unified to ensure comparability and information exchange among manufacturers, design institutes, and users. BS EN ISO 17769 provides a standard terminology system for pumps and pumping systems, forming the basis for standards such as ISO 9906 (pump testing).

💡 In engineering practice, unified definitions and units of pump parameters are the basis for selection calculations, performance comparison, and acceptance testing. BS EN ISO 17769 provides a unified terminology and symbol system, avoiding selection errors and contract disputes caused by definition differences.

1. Series Structure and Scope 📌

The series consists of two parts, both classified under ICS 23.080 (Pumps). They were developed by ISO/TC 115 (Pumps), converted to European standards by CEN/TC 197 (Pumps), and adopted as British Standards by BSI.

StandardTitlePublishedContent
BS EN ISO 17769-1:2012Liquid pumps and installation — General terms, definitions, quantities, letter symbols and units — Part 1: Liquid pumpsAug 2012Terminology and parameters of the pump itself
BS EN ISO 17769-2:2012Liquid pumps and installation — General terms, definitions, quantities, letter symbols and units — Part 2: Pumping systemAug 2012Terminology and parameters of the pumping system
⚠️ This series provides general terms and definitions for pumps and pumping systems, but does not specify performance test methods (which are given by ISO 9906 and other standards). Use it with the relevant testing and acceptance standards, and note unit conversion between SI and imperial systems.

2. Terminology System and Key Parameters 🔬

2.1 Part 1: Liquid pumps

Part 1 gives general terms, definitions, quantities, letter symbols, and units for liquid pumps, covering unified definitions of key parameters such as flow rate (Q), head (H), rotational speed (n), shaft power (P), efficiency (η), net positive suction head (NPSH), and specific speed (ns), with symbols, units, and relationships.

Key parameters include volume flow rate (volume of liquid delivered per unit time), head (effective energy per unit weight of liquid, expressed as a column of liquid in metres), net positive suction head (the margin of total head above the vapour pressure head at the pump inlet), and efficiency (the product of hydraulic, volumetric, and mechanical efficiencies). The standard gives unified definitions and symbols.

2.2 Part 2: Pumping system

Part 2 gives terms and parameters for the pumping system (the pump combined with piping, valves, and accessories), covering system head, piping losses, system resistance characteristics, and the operating point. The standard defines the intersection of the system characteristic curve and the pump characteristic curve (operating point) and gives expressions for system efficiency and energy consumption.

Key concepts of the pumping system include system head (the sum of static head and piping losses), the system characteristic curve (relationship between flow and required head), and the pump operating point (the intersection of the pump and system characteristic curves). The standard also unifies terms for system components such as control valves and variable-frequency drives.

ComparisonPart 1 (Liquid pumps)Part 2 (Pumping system)
ObjectParameters and terminology of the pump itselfSystem of pump and piping
Key parametersFlow, head, NPSH, efficiencySystem head, piping losses, operating point
Characteristic curvePump performance curveSystem characteristic curve
Typical usePump selection, performance comparisonSystem design, energy analysis
💡 Application point: the pump operating point is the intersection of the pump and system characteristic curves. Select so the operating point lies in the high-efficiency region, and consider the effect of system-resistance changes (valve adjustment, pipe ageing) on the operating point.

3. Unit Systems and Conversion 📏

The standard primarily uses the International System of Units (SI) and gives definitions and conversions for commonly used units. Flow rate is expressed in m³/s or m³/h, head in m, pressure in Pa or bar, and power in W or kW. For imperial units (gpm, ft, psi), the standard gives conversion relationships for compatibility with international engineering practice.

When using, state the unit system adopted to avoid calculation errors from mixing systems. The pump performance curve and system characteristic curve should use a consistent unit system, and careful attention to unit labelling and conversion is required in selection and acceptance.

🚨 Non-uniform pump parameter units are the most common source of error in selection and acceptance. Direct comparison of performance curves from different sources (e.g., different manufacturers, different unit systems) leads to serious deviations; always unify to one unit system before comparison and calculation.

4. Engineering Practice and Quality Control 🛠️

  • 🔍 Terminology unification: in pump enquiries, tenders, design documents, and contracts, use the terms and symbols specified in this standard to avoid ambiguity from definition differences.
  • 📊 Data exchange: when manufacturers and users exchange pump performance data, state the unit system and test conditions to ensure comparability.
  • 📋 Selection calculation: determine the pump operating point from system head and flow, and verify NPSH against the pump’s required NPSH (NPSHR).
  • 🧾 Documentation: pump technical documents should state standard terms, units, test standards, and performance data, forming complete traceability records.

5. Frequently Asked Questions ❓

❓ Q: What is the relationship between head and pressure?
A: Head is expressed as a column of liquid in metres, while pressure is in pascals or bars; the two are related through fluid density and gravitational acceleration (p = ρgh). At the same head, different fluid densities give different pressures.
❓ Q: What is the pump operating point?
A: The operating point is the intersection of the pump and system characteristic curves, representing the actual flow and head at which the pump runs under a given system resistance. Selection and operation should keep the operating point in the high-efficiency region.
❓ Q: How does NPSH relate to cavitation?
A: NPSH is the margin of liquid energy above vapour pressure at the pump inlet. When the available NPSH (NPSHA) is less than the required NPSH (NPSHR), cavitation occurs, damaging the pump and degrading performance.
❓ Q: How is pump efficiency calculated?
A: Pump efficiency = water power / shaft power. Water power = density × gravitational acceleration × flow × head. Efficiency reflects how well the pump converts mechanical energy into useful fluid energy.
🔒