🏠 BS EN ISO 16017 is the British Standard series on sampling and analysis of volatile organic compounds (VOCs) in indoor, ambient and workplace air, developed by ISO/TC 146 (Air quality) with CEN/TC 264 (Air quality), with UK participation through Technical Committee EH/2 (Air quality), Subcommittee EH/2/3 (Ambient atmospheres). The series specifies methods for analysing VOCs by sorbent-tube sampling — thermal desorption — capillary gas chromatography: Part 1 covers pumped sampling and Part 2 covers diffusive sampling. VOCs are important pollutant indicators in indoor air quality, workplace occupational exposure and ambient air quality assessment.
💡 Sorbent-tube sampling enriches trace VOCs from air onto a solid sorbent, which are then released by thermal desorption and injected for analysis. It offers high sensitivity, capable of measuring a wide range of VOCs at parts-per-billion (10⁻⁹ volume fraction) levels, and is one of the mainstream technologies for indoor and workplace air VOC monitoring.
1. Overview of the Series 📌
Classified under ICS 13.040.20 (Ambient atmospheres) and 13.040.30 (Workplace atmospheres). Part 1 (published 2001, corresponding to ISO 16017-1:2000) uses pumped sampling; Part 2 (published 2003, including Corrigendum No. 1) uses diffusive sampling. The two parts share essentially the same sorbent-tube, thermal-desorption and gas-chromatography analysis stages; the main difference is the sampling mode.
| Standard Number | Title | Sampling Mode | Typical Use |
| BS EN ISO 16017-1:2001 | Indoor, ambient and workplace air — Sampling and analysis of VOCs by sorbent tube/thermal desorption/capillary gas chromatography — Part 1: Pumped sampling | Pumped (active) sampling | Fixed-location, fixed-time sampling; accurate quantitation |
| BS EN ISO 16017-2:2003 | Indoor, ambient and workplace air — Sampling and analysis of VOCs by sorbent tube/thermal desorption/capillary gas chromatography — Part 2: Diffusive sampling | Diffusive (passive) sampling | Long-term exposure assessment; no power required |
⚠️ VOC sampling and analysis involves many organic compounds and is vulnerable to background contamination, sorbent breakthrough and sample loss. Strictly control sorbent-tube blanks, sampling flow rate/time, storage conditions and thermal-desorption parameters to ensure reliable results.
2. Structure and Technical Essentials 🔧
The two parts share the technical chain of “sorbent-tube sampling → thermal desorption → capillary GC separation → detector quantitation”, differing only in how the sample is introduced:
- Pumped sampling (Part 1): a sampling pump draws air through the sorbent tube at a constant flow rate so that VOCs are trapped by the sorbent. The sampling volume is accurately computed from flow rate and time, giving concentration.
- Diffusive sampling (Part 2): VOCs are passively adsorbed onto the sorbent tube (or diffusive sampler) through molecular diffusion, requiring no pump. Suited to long-term (hours to days) average concentration and personal exposure monitoring.
| Comparison | Part 1 — Pumped | Part 2 — Diffusive |
| Sampling driving force | Active pump aspiration | Passive molecular diffusion |
| Power required | Yes | No |
| Sampling time | Usually shorter (minutes–hours) | Longer (hours–days) |
| Concentration result | Instantaneous / period average | Long-term time-weighted average |
| Application | Fixed-site monitoring, investigation | Personal exposure, long-term assessment |
3. Key Technical Requirements: Sorbent Tubes and Sampling 🔬
The Standard places clear requirements on sorbent selection, tube preparation, sampling conditions and sample storage:
- Sorbents: commonly Tenax TA, carbon molecular sieves and graphitised carbon black; choose a single or multi-bed sorbent suited to the volatility and polarity of the target VOCs.
- Breakthrough volume: ensure the sampling volume does not exceed the sorbent’s breakthrough volume for the analytes, to avoid low results from breakthrough.
- Blank control: determine blanks for each batch of tubes; blank values must be below the specified limit; tubes should be sealed and stored in clean containers before and after sampling.
- Sampling parameters: calibrate the pump flow for pumped sampling and record temperature, humidity and pressure; record exposure time and temperature for diffusive sampling.
✅ It is recommended to take duplicate samples, field blanks and transport blanks at the site, and to perform spike-recovery checks on the tubes to evaluate sampling and desorption efficiency, ensuring data accuracy and completeness.
4. Key Technical Requirements: Thermal Desorption and GC Analysis 🎯
- Thermal desorption: heat the sorbent tube (e.g., 250 °C–350 °C) in an inert gas flow so the retained VOCs desorb and focus before transfer to the GC injector.
- Capillary gas chromatography: separate the VOC components of the desorbed gas on a capillary column, with a flame ionisation detector (FID), mass spectrometry (MS) or other detector for qualitative and quantitative analysis.
- Quantitation: prepare a calibration series from standard gas or standard solutions, draw a calibration curve for each compound, and calculate concentrations from peak area or peak height.
- Qualitation: initial identification by retention time, confirmed by mass spectrometry where necessary, to avoid interference from isomers or co-eluting compounds.
🚨 Thermal desorption involves high temperatures and flammable organics. Operate in a well-ventilated area and follow laboratory safety rules; manage toxic and flammable solvents carefully and dispose of waste liquids by category.
5. Engineering Practice and Applications 🛠️
- 🔍 Method selection: use pumped sampling when instantaneous or short-term concentration data are required; use diffusive sampling for long-term averages or individual exposure. Verify consistency between the two methods through comparison tests.
- 📊 Indoor air quality: VOCs are a major indoor air pollutant indicator; the series is used to evaluate VOC concentrations in newly decorated homes, offices and schools.
- 📋 Occupational exposure assessment: used for monitoring workplace air for toxic VOCs such as benzene, toluene and xylene against occupational exposure limits (OELs) and for personal exposure evaluation.
- 🧪 Typical applications: environmental monitoring, indoor air testing, occupational hygiene, material-emission tests (e.g., VOC release from building materials and furniture), air quality surveys and pollution source tracing.
6. Frequently Asked Questions ❓
❓ Q: Which is better, pumped or diffusive sampling?
A: They suit different scenarios. Pumped sampling is quantitatively accurate and suited to short-term fixed-site monitoring; diffusive sampling needs no power, can sample continuously over long periods, and suits personal exposure and long-term average assessment. Choose and verify consistency according to the monitoring objective.
❓ Q: Why does sorbent breakthrough occur?
A: When the sampling volume exceeds the sorbent’s adsorption capacity (breakthrough volume) for a compound, that compound escapes from the outlet of the tube, giving low results. Select a sorbent with sufficient capacity and control the sampling volume.
❓ Q: How does thermal desorption differ from solvent desorption?
A: Thermal desorption heats the sorbent tube to release all retained VOCs directly into the GC — no solvent interference, high sensitivity, and the tubes can be reused; solvent desorption elutes with solvent, being simpler but introducing solvent peaks. This series uses thermal desorption.
🔍 Q: How do you judge whether a sorbent-tube blank is acceptable?
A: Analyse an unsampled tube through the same thermal-desorption-GC procedure as samples; the blank peak areas of target compounds should be below the specified limit (typically around the method detection limit). Otherwise re-condition or replace the tube.