BS EN ISO 14673 — Milk and Milk Products: Determination of Nitrate and Nitrite Contents

Milk and Milk Products — Determination of Nitrate and Nitrite Contents Series

🥛 The BS EN ISO 14673 series is a set of British Standards implementing the European standard EN ISO 14673 in the field of milk and milk products analysis, specifying methods for the determination of nitrate and nitrite contents. The series was prepared by the relevant ISO/TC 34 (Food products) subcommittees together with CEN, with UK participation entrusted to Technical Committee AW/5 (Milk and milk products). Nitrate and nitrite are safety indicators of concern in dairy products (especially milk powder, cheese and infant formulae); excessive intake of nitrite and nitrate can affect health, so accurate determination methods are needed for monitoring. The ICS classification is 67.100.10 (milk and milk products).

💡 The key to determining nitrate and nitrite is reducing nitrate to nitrite and quantifying it. The ISO 14673 series provides several reduction and analysis routes, balancing precision (reference method) with throughput (routine methods) for different laboratories and testing scenarios.

1. Series Composition 📌

The series comprises three documents (2004 edition, each incorporating Corrigendum No. 1), corresponding to three determination methods:

StandardYearTitle / SubjectMethod Principle
BS EN ISO 14673-12004Method using cadmium reduction and spectrometryCadmium column reduction + spectrophotometric quantification (reference/arbitration method)
BS EN ISO 14673-22004Method using segmented flow analysis (Routine method)Segmented flow analysis (SFA), automated on-line determination
BS EN ISO 14673-32004Method using cadmium reduction and flow injection analysis with in-line dialysis (Routine method)Flow injection analysis (FIA) + in-line dialysis
⚠️ Edition continuity: the 2004 edition supersedes the 2001 edition, with Corrigenda No. 1 (15079/15080/15081) correcting the foreword pages and incorporating Annex ZA. Verify the edition and corrigendum status when using.

2. Cadmium Reduction and Spectrometry (Part 1) 🧪

Part 1 specifies the determination of nitrate and nitrite contents in milk and milk products by cadmium reduction and spectrometry. After extraction and deproteinisation, nitrate is reduced to nitrite through a cadmium column (or cadmium granules); nitrite reacts with a colour reagent to form a coloured compound, whose absorbance is measured with a spectrophotometer at a specified wavelength for quantification. This method has high precision and is commonly used for arbitration and method validation.

3. Segmented Flow Analysis (Part 2) 🔬

Part 2 specifies the determination of nitrate and nitrite contents by segmented flow analysis (SFA), a routine method. Samples are automatically injected and processed on-line, with reduction, colour development and photometric detection performed within a flowing system. It is suitable for rapid determination of large numbers of samples, offering good precision and high throughput.

4. Cadmium Reduction and Flow Injection Analysis with In-Line Dialysis (Part 3) ⚗️

Part 3 specifies the determination of nitrate and nitrite contents by cadmium reduction and flow injection analysis (FIA) with in-line dialysis, also a routine method. FIA mixes reagents and samples under controlled conditions in tubing, and in-line dialysis removes interfering substances such as proteins, enabling fast, automated determination suitable for routine quality control and monitoring.

🚨 The reliability of nitrate/nitrite determination depends on sample preparation and control of the colour reaction. Complete deproteinisation, cadmium reduction efficiency, colour development time and wavelength selection, and the linearity of the standard curve all directly affect quantification accuracy; improper operation produces significant bias.

5. Engineering Practice and Quality Control Applications 🛠️

  • 🔍 Raw milk monitoring: monitor nitrate/nitrite in raw milk and raw milk powder to prevent contamination exceeding limits.
  • 📋 Product release: milk powder, cheese and infant formulae are tested per the standard methods as a basis for release and safety verification.
  • 🏭 Laboratory method selection: use the Part 1 reference method for arbitration and validation, and the Part 2/3 routine methods for batch monitoring.
  • 📊 Regulatory compliance: results are compared with nitrate/nitrite limits in food regulations to judge conformity and support food safety supervision.

6. Frequently Asked Questions ❓

❓ Q: Why must nitrate be reduced to nitrite?
A: The standard methods quantify via the colour reaction of nitrite. Nitrate must first be reduced to nitrite by cadmium reduction, then quantified by colour development and photometry, giving the total (or separate) nitrate and nitrite contents.
❓ Q: What is the difference between Part 1 and Parts 2/3?
A: Part 1 is cadmium reduction and spectrometry (reference/arbitration method) with high precision; Part 2 is segmented flow analysis (routine method) and Part 3 is cadmium reduction and flow injection analysis with in-line dialysis (routine method), both suited to fast, large-batch determination.
❓ Q: Why must samples be deproteinised?
A: Dairy products contain large amounts of protein, which interferes with colour development and photometric measurement. Deproteinisation removes matrix interference so that the reduction and colour reactions proceed quantitatively.
🔍 Q: How are results used for food safety?
A: Results are compared with standard limits to judge conformity; non-conforming samples are traced and handled to prevent unsafe products from reaching the market.
🔒