💧 BS EN ISO 14403 is the British Standard (BSI) series that adopts the European Standard, itself identical to an International Standard, for determination of total and free cyanide in water using flow analysis. The series specifies methods using flow injection analysis (FIA) and continuous flow analysis (CFA): Part 1 covers FIA, and Part 2 covers CFA. Cyanide (CN⁻) is highly toxic and widely used in electroplating, mining, metallurgy, and the chemical industry, making it an important indicator in water-quality monitoring and wastewater-discharge control. The technical content was jointly prepared by ISO/TC 147 “Water quality” and CEN/TC 230 “Water analysis”, and introduced into the British Standards system by BSI.
The series covers ICS 13.060.50 (Determination of chemical substances in water) and has two parts:
| Standard | Title | Main Content |
|---|---|---|
| BS EN ISO 14403-1:2012 | Water quality — Determination of total cyanide and free cyanide using flow analysis (FIA and CFA) — Part 1: Method using flow injection analysis (FIA) | Specifies determination of total and free cyanide by flow injection analysis |
| BS EN ISO 14403-2:2012 | Water quality — Determination of total cyanide and free cyanide using flow analysis (FIA and CFA) — Part 2: Method using continuous flow analysis (CFA) | Specifies determination of total and free cyanide by continuous flow analysis |
Both parts were published in 2012; Part 2 supersedes BS EN ISO 14403:2002. In the UK, technical responsibility is vested in subcommittee EH/3/2, Physical chemical and biochemical methods.
Cyanide determination is based on chemical conversion and photometric detection: cyanide in the sample reacts with a colour-developing reagent under specific conditions to form a coloured compound, measured by a photometric detector at a specific wavelength, quantified from a calibration curve. A common colour system is the König reaction using chloramine-T and pyridine-barbituric acid (or isonicotinic acid-pyrazolone), producing a blue or purple compound.
The difference between total and free cyanide lies in pretreatment: free cyanide is measured directly after acidification; total cyanide requires distillation or acid decomposition of complex cyanides, with HCN distilled and absorbed, then measured. Total cyanide reflects all releasable cyanide; free cyanide reflects the biologically toxic free CN⁻.
Both methods achieve automated flow analysis but differ in injection and mixing:
| Method | Injection | Features |
|---|---|---|
| Flow injection analysis (FIA, Part 1) | Inject sample into a continuously flowing carrier stream | Dispersion and reaction occur in the tubing; rapid, low sample volume |
| Continuous flow analysis (CFA, Part 2) | Continuously pump sample and reagents for mixing | Steady-state reaction; suitable for large sample numbers continuously |
Both methods should eliminate interferences (e.g., sulphide, nitrite, oxidants, and heavy-metal complexing agents) to ensure selectivity; detection limits and applicability follow the Standard, validated by quality-control samples and spike recovery.
Water cyanide determination is widely used in environmental monitoring, industrial wastewater, and drinking-water safety: