💊 BS EN ISO 13408 is the UK adoption by BSI of the ISO 13408 series covering aseptic processing of health care products. Aseptic processing is the process by which sterile products are assembled, filled and sealed in a controlled clean environment when terminal sterilization is not possible, using operations such as sterile filtration and aseptic filling. The series specifies requirements for facilities, processes, equipment, personnel and environmental control of aseptic processing, and is the core specification for the production of sterile pharmaceuticals, biologics and medical devices. The series comprises seven parts, superseding relevant parts of BS EN 13824:2004.
Some parts of this series were sourced from scanned documents; the technical content is compiled from publicly available domain knowledge and the authoritative text remains the official BSI publication.
BS EN ISO 13408 applies to health care products manufactured by aseptic processing (rather than terminal sterilization), including injectables, biologics and sterile medical devices. The standard covers the full chain of aseptic processing: cleanroom and zone design, air filtration and particle monitoring, sterilization of equipment and containers, sterile filtration, personnel gowning and behaviour, process validation and environmental monitoring.
The standard is organised as “general requirements (Part 1) + specialised processes (Parts 2-7)”: Part 1 gives general requirements for aseptic processing; subsequent parts give dedicated requirements for filtration, lyophilization (freeze-drying), isolation technologies, sterilization in place (SIP), filling equipment and powder filling.
The table below lists the subject and scope of each part.
| Part | Subject | Scope | Edition |
|---|---|---|---|
| BS EN ISO 13408-1 | General requirements | General requirements for aseptic processing | 2015 (incl. Amd 1:2013) |
| BS EN ISO 13408-2 | Filtration | Sterile filtration | 2011 |
| BS EN ISO 13408-3 | Lyophilization | Freeze-drying | 2011 |
| BS EN ISO 13408-4 | Isolation technologies | Isolation technologies | 2011 |
| BS EN ISO 13408-5 | Sterilization in place | Sterilization in place (SIP) | 2011 |
| BS EN ISO 13408-6 | Isolator systems | Isolator systems | 2011+A1:2013 |
| BS EN ISO 13408-7 | Alternative methods for aseptic processing | Alternative aseptic processing methods | 2015 |
In the pharmaceutical and biologics industry, the 13408 series is the basis for design, validation and daily operation of aseptic production facilities. Engineering teams design cleanrooms and HVAC per the facility and zoning requirements. Validation teams prepare IQ/OQ/PQ protocols for filtration, lyophilization, SIP and isolators per the parts. Production teams organise aseptic operations and media-fill simulation tests per the personnel behaviour requirements. Quality teams manage the sterility assurance state through environmental monitoring, integrity tests and microbial data.
Isolation technology (isolators) significantly reduces the disturbance of the aseptic environment by operators and improves contamination control; it has become an advanced trend in aseptic filling lines. Media-fill simulation is the “gold standard” for verifying the overall sterility assurance of the aseptic process.