🩺 BS EN ISO 11073 is the British Standards Institution (BSI) adoption of the international standard ISO/IEEE 11073 (Health informatics — Point-of-care medical device communication / Personal health device communication) as the European standard. The series defines the communication and data-exchange standards between medical devices — particularly point-of-care and personal health devices — and health information systems, enabling interoperability between devices from different manufacturers and the health IT ecosystem. It is maintained by BSI Technical Committee IST/35 (Health informatics) and classified under ICS 35.240.80 (IT applications in health care).
The ISO/IEEE 11073 family is organised into three parts — framework, device specialisations and transport: 10xxx nomenclature and terminology (e.g. Part 10102 annotated ECG, 10103 implantable cardiac device nomenclature) unifies medical dimensions and coding; 104xx device specialisations define the data model and services for each personal health device (pulse oximeter, blood pressure monitor, thermometer, glucose meter, weighing scale, ECG, independent living monitor, etc.); 20601 / 30200 / 30400 define the application protocol (Optimized Exchange Protocol) and transport interfaces (cabled connection, interface profiles). The system allows “plug-and-play” health data to reliably enter the Electronic Health Record (EHR).
| Part / Document | Main Content | Topic |
|---|---|---|
| BS EN ISO 11073-10102 / 10103 (2013–2014) | Nomenclature: annotated ECG, implantable cardiac device | 10xxx nomenclature system |
| BS EN ISO 11073-10404 (2011) | Pulse oximeter | Oximeter data model and services |
| BS EN ISO 11073-10407 / 10408 (2011–2012) | Blood pressure, body thermometer | BP and temperature device specialisation |
| BS EN ISO 11073-10406 / 10415 / 10417 / 10418 (2011–2014) | Basic ECG, weighing scale, glucose meter, INR monitor | Common personal health device specialisations |
| BS EN ISO 11073-10419~10425 (2012–2016) | Body composition, respiration, 24-part extension | Body-fat, sleep-respiration and extension devices |
| BS EN ISO 11073-10471 / 10472 (2011–2012) | Independent living, medication monitor | PHD home monitoring devices |
| BS EN ISO 11073-20601 (2016) | Application protocol: Optimized Exchange Protocol | Session and data exchange between PHD and gateway |
| BS EN ISO 11073-30200 (2005+A1) / 30400 (2012) | Transport: cabled connection / interface profiles | Device transport mechanism and interface definition |
The nomenclature unifies medical object identifiers (term codes), unit systems and attribute descriptions, ensuring “oxygen saturation 95%” is expressed consistently in any implementation — the prerequisite for semantic interoperability.
Each device defines its measurement data objects, numeric types (e.g. SpO₂, pulse rate), events and states (alarm, battery, device fault), and specifies value representation, units and extension rules so gateways and EHRs can interpret device data in a standard way.