🐟 BS EN ISO 07346 (ISO 7346) is the method series for determining the acute lethal toxicity of substances to a freshwater fish, using the zebrafish (Brachydanio rerio, now Danio rerio) as the test organism. This batch covers three parts: Part 1 is the static method, Part 2 the semi-static method, and Part 3 the flow-through method. Developed by ISO/TC 147 (Water quality) with UK participation through the EH/3 Water quality technical committee and its biological-methods subcommittee, and adopted by BSI as a British Standard, it is cross-referenced with Part 5 of the BS 6068 series (BS 6068-5.2 / 5.3 / 5.4).
💡 Acute fish toxicity is a foundational endpoint in chemical environmental risk assessment (e.g., REACH) and a common indicator for ecotoxicological evaluation of industrial wastewater. Through standardised conditions (fish age, water quality, loading, temperature, and observation procedure), ISO 7346 ensures that LC50 data from different laboratories are comparable.
1. Series Overview and Scope 📌
| Standard | Title | Year |
| BS EN ISO 7346-1:1998 | Static method | 1998 |
| BS EN ISO 7346-2:1998 | Semi-static method | 1998 |
| BS EN ISO 7346-3:1998 | Flow-through method | 1998 |
The three methods share the same principle: expose zebrafish to a series of concentrations of the test substance and record mortality over a specified observation period (usually 96 h), calculating the median lethal concentration (LC50). They differ in how the test solution is renewed: the static method does not renew the solution during the test and suits stable, low-volatility substances; the semi-static method renews the solution every 24 h and suits moderately stable substances; the flow-through method continuously renews the solution, suiting volatile, readily degradable, or adsorbing substances while maintaining a constant exposure concentration.
⚠️ Method selection is closely tied to substance properties: for volatile, readily hydrolysing, adsorbing, or rapidly degrading substances, the static method will underestimate toxicity because the exposure concentration drops significantly — prefer the semi-static or flow-through method and measure the actual concentration in the test solution.
2. Series Composition and Technical Points 🔧
2.1 BS EN ISO 7346-1: Static Method
The static method is the simplest: the test solution and test fish (at a specified body load) are added to the test vessel, and the solution is not renewed during the 96 h observation period. The standard specifies the number of fish, vessel volume, dissolved-oxygen and temperature control, the observation and recording time points for mortality, and the measurement of pH and dissolved oxygen at the end. It suits chemically stable, water-soluble, and non-volatile substances.
2.2 BS EN ISO 7346-2: Semi-Static Method
The semi-static method renews the test solution every 24 h (or at a stated interval) on top of the static approach, mitigating the concentration drop from degradation, volatilisation, and adsorption while keeping the operation controllable. The standard specifies the renewal procedure, temperature equilibration of old/new solutions, and verification of the exposure concentration. It suits substances with a certain degradation rate over the test duration.
2.3 BS EN ISO 7346-3: Flow-Through Method
The flow-through method maintains a constant exposure concentration by continuous or near-continuous solution renewal and removes metabolic waste, coming closest to the “constant concentration” requirement. The standard specifies the flow rate, dilution system, and concentration-equilibration time; the system is more complex but the toxicity determination is most reliable for labile substances. LC50 values from the three methods should be compared only after noting the method type.
💡 Engineering advice: in the screening stage, first use the static method to quickly estimate the acute toxicity range; then, according to substance properties, use the semi-static or flow-through method for the definitive test. Report the LC50 with its 95 % confidence interval, the method, and the measured actual concentration.
3. Key Technical Requirements and Test Elements 🎯
- Test organism: use healthy zebrafish juveniles or adults of consistent age/size and acclimation state, acclimated to the specified water quality and temperature before testing; do not feed or feed per the standard during the test.
- Test solution and concentration series: set at least five geometrically spaced concentration groups plus one blank control; prepare the solution with pure water or standard dilution water; for poorly soluble substances describe the solubilising and dispersing method.
- Temperature and water quality: control the test water temperature per the standard (e.g., within 20 °C–25 °C and consistent), keep dissolved oxygen above the specified level (e.g., ≥ 60 %–70 % of air saturation), and maintain pH within the specified range.
- Loading and vessel: the fish body load (fish mass per litre of water) must not exceed the specified value; vessel material should avoid adsorbing the test substance; arrange lighting and photoperiod per the standard.
- Observation and result calculation: record mortality at 24, 48, 72, and 96 h; compute the LC50 and confidence interval by a statistical method (e.g., probit); report the test conditions and validity criteria.
🚨 Animal ethics and safety: follow the 3R principle (reduce, replace, refine), using only the necessary number of fish; dispose of surviving fish ethically at the end; when handling volatile or toxic substances wear appropriate protection and ensure ventilation and proper waste treatment.
4. Engineering Practice and Applications 🛠️
- Chemical risk assessment: provide acute fish toxicity (LC50) data for registration and REACH notification of pesticides, industrial chemicals, and pharmaceuticals, as the basis for aquatic environmental hazard classification.
- Ecotoxicological evaluation of industrial wastewater: perform acute fish toxicity tests on discharged effluent to evaluate the detoxification effect of treatment processes and the ecological risk to receiving waters.
- Environmental monitoring and emergency response: carry out rapid toxicity screening for sudden pollution events or point-source discharges to support emergency decisions and remediation.
- Method development and quality control: laboratories verify test-system sensitivity with a reference toxicant (e.g., potassium dichromate) and ensure data quality through proficiency testing.
5. Frequently Asked Questions ❓
❓ Q: What does LC50 mean, and how long does the test take?
A: LC50 (median lethal concentration) is the substance concentration that kills 50 % of the test fish within a stated exposure time; this series uses 96 h as the formal observation period, also recording 24/48/72 h data to observe how toxicity changes with time.
🔍 Q: Can the results of the static, semi-static, and flow-through methods be directly compared?
A: For stable substances the three methods give similar results; for volatile/readily degradable substances the static method overestimates the LC50 (underestimates toxicity) because the exposure concentration drops, and the difference from the semi-static and flow-through results is significant. Ensure the method is consistent and report the measured actual concentration when comparing.
❓ Q: Why use the zebrafish as the test fish?
A: The zebrafish is small, breeds quickly, is inexpensive to maintain, is sensitive to toxicity, and its results are widely comparable internationally; it is one of the standard model organisms for OECD/ISO acute fish toxicity tests, enabling standardisation and mutual recognition of data.
🔍 Q: Will insufficient dissolved oxygen affect the result?
A: Yes. Too-low dissolved oxygen causes non-specific stress and even death of the fish, interfering with the true toxicity evaluation. The standard sets a lower limit for dissolved oxygen; monitor during the test and aerate or improve ventilation as needed.