🔊 BS EN ISO 3822 is the British implementation of the EN ISO 3822 series corresponding to ISO 3822, developed by relevant technical bodies of ISO/TC 43 (Acoustics) and CEN/TC 126 (Building acoustics), approved by CEN, and transposed in the United Kingdom by Subcommittee EH/1/6 (Building acoustics) of BSI Technical Committee EH/1 (Acoustics). The series specifies laboratory test methods for noise emission from appliances and equipment (draw-off taps, mixing valves, in-line valves, and accessories) used in water supply installations, providing a basis for evaluating the noise characteristics of sanitary fittings and pipe accessories, and for acoustic control in building water supply and drainage design, residential, and public buildings.
💡 Water noise is a common disturbance in residential and hotel buildings: cavitation and turbulence noise generated as water flows through taps, valves, and fittings propagates along pipes and radiates into adjacent rooms. A unified, reproducible laboratory method makes noise indicators of different products comparable, supporting the selection and acceptance of low-noise products.
1. Series Structure and General Framework 📌
BS EN ISO 3822 is organized by test object and condition: Part 1 specifies the general measurement method; Part 2 specifies mounting and operating conditions for draw-off taps and mixing valves; Part 3 covers noise testing of in-line valves and appliances; Part 4 gives supplementary requirements (e.g., drainage devices). The parts work together to cover the main noise sources in water supply installations.
| Part | Subject | Main Content | Edition |
| BS EN ISO 3822-1 | Method of measurement | Sound pressure/power measurement method, test rig, test room requirements, result presentation | 1999+A1:2008 |
| BS EN ISO 3822-2 | Mounting and operating conditions for draw-off taps and mixing valves | Mounting, supply pressure, and flow conditions for taps and mixing valves | 1996 |
| BS EN ISO 3822-3 | Noise testing of in-line valves and appliances | Mounting, operating, and test requirements for in-line valves and appliances | 1997+A1:2009 |
| BS EN ISO 3822-4 | Supplementary requirements (part) | Supplementary noise test requirements (e.g., drainage devices) | 1997 |
⚠️ Noise measurement is highly sensitive to mounting conditions: the mounting method of taps and mixing valves (fixing stiffness, sealing, and piping conditions) directly affects radiated noise; supply pressure and flow must also be controlled at the conditions set by the standard, otherwise results are not comparable.
2. Measurement Method and Apparatus 🔬
BS EN ISO 3822-1 specifies the method for measuring water noise in a dedicated acoustic test rig and test room: the device under test is installed on a standardized supply and drainage pipework, and under set pressure and flow, a microphone measures the radiated sound pressure level, from which the sound power level or a level at a specified reference point is derived. The standard specifies the rig structure, microphone positions, background noise correction, and data processing.
- Test rig: standardized water supply system, pressure regulator, flow meter, and test room.
- Microphone positions: specified measurement points and acoustic environment for reproducibility.
- Condition setting: supply pressure (e.g., 3 bar) and flow per standard (e.g., two flow levels Q1, Q2).
- Data processing: background noise correction, level averaging, results expressed in octave bands or specified frequency bands.
3. Testing of Taps, Mixing Valves, and In-line Appliances ⚙️
BS EN ISO 3822-2 specifies mounting and operating conditions for draw-off taps and mixing valves: recommended mounting arrangements, supply pressure, and water flow conditions (including Q1/Q2 flow levels) for reproducible testing. BS EN ISO 3822-3 specifies noise test conditions for in-line valves (e.g., stop valves, pressure-reducing valves) and appliances, with standardized mounting and operating conditions.
🚨 Cavitation at high pressure and high flow velocity is the main source of water noise. Selecting low-noise taps and valves, controlling flow velocity and pressure, and using flexible connections and vibration-isolating supports can significantly reduce transmission of pipework noise into building structures.
4. Engineering Practice Essentials 🛠️
- 🔍 Product selection: select low-noise taps, mixing valves, and accessories based on noise indicators (level versus flow relationship).
- 🔧 System design: control in-pipe flow velocity and water pressure to avoid excessive pressure differences causing cavitation noise.
- 📊 Acceptance testing: spot-check noise indicators of batch products per the standard method and compare with supplier data and standard limits.
- 📋 Acoustic control: combine pipework vibration isolation, resilient hangers, and sound-insulating constructions for comprehensive building water-noise control.
5. Frequently Asked Questions ❓
❓ Q: What noise does BS EN ISO 3822 test?
A: It tests the noise emission from appliances and equipment (draw-off taps, mixing valves, in-line valves) in water supply installations at set pressure and flow, to evaluate noise characteristics and enable product comparison.
❓ Q: Why test in a laboratory rather than on site?
A: On-site noise is strongly affected by building structure, pipework layout, and environment, making comparison difficult. The laboratory uses standardized mounting and measurement conditions so noise indicators of different products are comparable and reproducible.
❓ Q: What is the difference between Parts 2 and 3?
A: Part 2 addresses mounting and operating conditions for draw-off taps and mixing valves; Part 3 addresses test conditions for in-line valves and appliances. They cover different water-supply noise sources.
🔍 Q: How can building water noise be reduced?
A: Select low-noise products, control flow velocity and pressure, use flexible connections and resilient supports, provide pipework vibration isolation and sound insulation, and evaluate noise levels per standard data at the design stage.