BS EN ISO 1938 — Geometrical Product Specifications (GPS) Dimensional Measuring Equipment Series

Standard Series (Part 1: Plain Limit Gauges of Linear Size & Part 2: Reference Disk Gauges)

📏 BS EN ISO 1938 is the BSI-published series adopting the European Standard EN ISO 1938, identical to ISO 1938. It belongs to the Geometrical Product Specification (GPS) framework and specifies requirements for dimensional measuring equipment, focusing on plain limit gauges of linear size and reference disk gauges. Limit gauges (GO/NO-GO, plain plug and ring gauges) are among the most traditional and reliable dimensional inspection tools in manufacturing: by the rule “the GO gauge must pass and the NO-GO gauge must not”, they quickly verify whether a hole or shaft lies within the permitted tolerance zone, independent of the operator’s reading skill. The series has Part 1 (plain limit gauges) and Part 2 (reference disk gauges). It supersedes and consolidates British standards such as the former BS 969:2008.

💡 BSI Technical Committee TDW/4 (Technical Product Realization) manages UK participation, aligned with ISO/TC 213 (Dimensional and geometrical product specifications and verification) and CEN/TC 290. Notably, Part 1 does not cover the “setting plug and setting ring gauges” of ISO/R 1938:1971; in the UK, BS 4064 and BS 4065 cover plain setting rings.

1. Series Overview and Scope 🎯

The GPS framework spans the full chain of “size — tolerance — measurement — verification” for products. Within it, ISO 1938 sits at the “measuring equipment” layer, providing design, manufacture, calibration and use requirements for shop-floor rapid size inspection gauges. The series is classified under ICS 17.040.10 (tolerances of size) and 17.040.30/17.040.40 (measuring instruments).

StandardTitleMain Content
BS EN ISO 1938-1:2015GPS — Dimensional measuring equipment — Part 1: Plain limit gauges of linear sizeDimensions, tolerances, marking, wear and use of plain plug and ring (GO/NO-GO) gauges
BS EN ISO 1938-2:2017GPS — Dimensional measuring equipment — Part 2: Reference disk gaugesRequirements and calibration of reference disk gauges used to verify (e.g. internal-diameter) instruments
⚠️ A gauge acceptance does not mean the part dimension is absolutely precise: the gauge tolerance system reserves gauge tolerance and wear limits for manufacture, and results are affected by the gauge’s own condition. Gauges must be calibrated periodically and wear monitored.

2. Part 1: Plain Limit Gauges of Linear Size 🧰

BS EN ISO 1938-1:2015 specifies the design and use of plain limit gauges (plug and ring gauges):

  • GO and NO-GO: the GO gauge is made to the maximum-material size and must enter freely; the NO-GO gauge is made to the minimum-material size and must not pass. Together they judge size conformity.
  • Gauge tolerances: manufacturing tolerance and wear limits of the gauge itself are specified so the gauge’s acceptance boundary falls outside the workpiece tolerance zone and the risk of shipping bad parts is controlled.
  • Marking and construction: nominal size, tolerance designation, identification and handle structure requirements.
  • Usage procedure: cleaning, lubrication, use temperature and handling technique to reduce human error.
💡 Taylor’s principle: the GO gauge should be a full-length complete-profile gauge, simultaneously checking size and form (roundness, straightness); the NO-GO checks size at two contact points only. Following this principle improves inspection effectiveness.

3. Part 2: Reference Disk Gauges 🔮

BS EN ISO 1938-2:2017 specifies the requirements for reference disk gauges. A reference disk gauge is a gauge with a precision external disk, typically used to calibrate internal-diameter micrometers and probes, or as an intermediate dimensional reference. Technical points include:

  • Geometric requirements: diameter accuracy, roundness and surface quality of the gauge disk.
  • Calibration: traceability methods for measuring the disk so values trace to national standards.
  • Use and maintenance: protect the disk from impacts and contamination; clean and rust-protect before and after use.
  • Paired applications: used with read-out measuring instruments to set zero or establish a measurement datum.
🚨 The accuracy class of the disk gauge must be higher than the instrument under calibration: if the disk’s own error is at the same level as the instrument’s, the calibration is meaningless. Verify the certificate and validity of the disk before use.

4. Key Requirements Comparison 🔍

TopicPart 1 (Plain Limit Gauges)Part 2 (Reference Disk Gauges)
Device typePlain plug and ring gauges (GO/NO-GO)Precision external disk gauges
Main purposeWorkpiece size acceptanceInternal-diameter instrument calibration/reference
JudgementGO/NO-GO pass judgementNumerical comparison calibration
Key characteristicsGauge tolerance and wear limitsDiameter accuracy and traceability
MaintenanceCleaning, rust protection, wear monitoringImpact/contamination protection, periodic calibration

5. Engineering Practice 🛠️

  • Shop-floor inspection: use GO/NO-GO gauges for rapid acceptance of hole and shaft sizes in high-volume production, improving efficiency and lowering cost.
  • Metrology management: include gauges in the calibration plan with periodic recalibration and wear records.
  • Instrument verification: periodically verify internal-diameter instruments with reference disk gauges so process-capability data remain reliable.
  • Fit with tolerance system: gauge sizes are designed to the tolerance zones of BS EN ISO 286, directly matching drawing tolerance designations.

6. FAQ ❓

❓ Must a part rejected by GO/NO-GO gauges always be rejected?
Answer: Generally yes. But gauge judgement is affected by temperature, oil film and gauge wear; for borderline cases, re-measure or verify with a higher-precision instrument before the final decision.
❓ Do gauges need periodic calibration?
Answer: Yes. Gauges wear with long use; a worn GO gauge can pass out-of-tolerance parts. Set a calibration period and monitor wear.
❓ What is the relationship between Part 1 and Part 2?
Answer: Part 1 covers limit gauges for workpiece inspection; Part 2 covers reference disk gauges for verifying measuring instruments. They differ in purpose but are complementary documents in the same GPS measuring-equipment framework.
❓ Does a temperature difference between gauge and workpiece matter?
Answer: Yes. Thermal expansion changes both sizes; the standard prescribes use and judgement at the reference temperature (normally 20 °C), and correction is needed when the temperature difference is significant.
❓ When should limit gauges be used instead of measuring instruments?
Answer: When only “within tolerance” judgement is needed and the batch is large with a clear tolerance, gauges are faster and more economical; use read-out instruments when numerical values are needed for statistical process control (SPC).
🔒
正在加载下载地址,请稍候 10 秒

Leave a Reply

Your email address will not be published. Required fields are marked *