⏳ BS EN ISO 00899 (i.e. BS EN ISO 899) is the British adoption of the European standard EN ISO 899, identical to the ISO 899 series, which specifies methods for determining the creep behaviour of plastics. Creep is the progressive deformation of a material under constant stress over time. It is especially important for plastics — viscoelastic materials that continue to deform under sustained load, potentially affecting the long-term reliability of structural parts, pipes, and seals. The ISO 899 series determines parameters such as creep strain and creep modulus through tensile and flexural creep tests, providing the basis for long-term load-bearing design. The series was prepared by ISO/TC 61 (Plastics) in cooperation with CEN/TC 249 (Plastics).
This series applies to the determination of creep behaviour of plastics and plastic products under constant stress (or constant load). Tests are carried out at specified temperature and humidity, applying a constant load and recording the specimen deformation with time, from which creep strain, creep modulus, and creep fracture parameters are calculated. The standard gives specimen dimensions, loading conditions, measurement times, and data-processing methods.
Two parts are included in this batch:
| Standard | Corresponding ISO | Main Content | Loading Mode |
|---|---|---|---|
| BS EN ISO 899-1:2003+A1:2015 | ISO 899-1:2003+Amd.1:2015 | Tensile creep: constant tensile stress, creep strain and modulus | Tension |
| BS EN ISO 899-2:2003+A1:2015 | ISO 899-2:2003+Amd.1:2015 | Three-point loading flexural creep: constant bending stress, deflection and modulus | Bending |
BS EN ISO 899-1 specifies creep determination under constant tensile stress. The specimen is subjected to an axial constant load, and the elongation of the gauge length is measured as a function of time, giving the creep strain-time curve, from which the tensile creep modulus is calculated. Amendment A1:2015 updates Annex A.2 (regarding test-condition expression). Tests are usually carried out at specified temperature and humidity; accelerated tests or long-term monitoring may be used where necessary.
BS EN ISO 899-2 specifies creep determination under three-point bending loading. The specimen rests on two supports, a constant load is applied at the centre, and the mid-span deflection is recorded with time, from which the flexural creep strain and flexural creep modulus are calculated. Three-point flexural creep more closely matches the actual loading of beam- and plate-type components. Amendment A1:2015 revises certain content.
The test should specify and record temperature, humidity, and load level. Temperature and humidity markedly affect creep and should be tightly controlled and stated in the report. The load level should keep the specimen in the elastic or viscoelastic range, avoiding instantaneous overload.
The load should be applied rapidly and smoothly to the set value and held constant, avoiding impact and fluctuation. The instantaneous strain on loading and the subsequent time-dependent creep strain should be recorded separately for analysis.
A deformation-measuring device of adequate accuracy should be used, recording gauge-length deformation continuously or at set time intervals. Measurement should cover a sufficient duration (from hours to thousands of hours) to reflect long-term creep behaviour.
From the deformation data, calculate creep strain, creep modulus (stress divided by creep strain), and give the creep curve. Results should state test conditions, specimen dimensions, load level, and test duration, and where appropriate compare multiple load levels.