BS EN ISO 00140 — Measurement of Sound Insulation in Buildings and of Building Elements (ISO 140) Standard Series

Acoustics — Measurement of Sound Insulation in Buildings and of Building Elements (UK implementation of EN ISO 140)

📐 BS EN ISO 00140 is the UK implementation of the ISO 140 series (Acoustics — Measurement of sound insulation in buildings and of building elements) together with EN ISO 140, overseen in the UK by BSI Technical Committee EH/1 (Acoustics) through subcommittee EH/1/6 (Building acoustics). The series defines unified test methods for determining the airborne and impact sound insulation of building elements and complete buildings, and is the core measurement standard in building-acoustic design, product certification and final acceptance. It supplies the data used by single-number rating standards such as ISO 717. The complete set comprises 11 documents.

⚠️ Scanned version, written from public domain knowledge: the source material for this series is scanned (SCAN>0); the technical content below is summarised from publicly known information in the field, and the authoritative text is the official BSI publication.
💡 Note the relationships: ISO 140 (this classic series, 1978–2009 editions) is historically continued by ISO 10140 (laboratory replacement series), while field measurement has moved to ISO 16283. ISO 140 is still widely referenced in engineering literature and legacy certification, so understanding its methodology remains essential.

1. Scope and General Overview 📌

Sound-insulation measurement answers two questions: “how much sound does an element (wall, floor, door, window) block”, and “how well do adjacent rooms in a finished building actually isolate sound”. ISO 140 specifies both laboratory measurement and field measurement procedures, and distinguishes airborne sound (sound generated in the source room transmitted through the element into the receiving room) from impact sound (structure-borne sound excited on the floor, e.g. by footsteps or dragging furniture).

The scope covers: laboratory measurement of walls, floors, doors and windows; field measurement of airborne insulation of finished buildings and facades; measurement of the improvement of impact sound by floor coverings (carpets, pads, floating layers); measurement of access-floor (raised-floor) insulation; and measurement of indoor noise from rain striking elements. The parts are organised logically: basic methods, specific elements, improvement measurements and special situations each have their own document.

2. Series Structure and Technical Content 🔧

The table below summarises the 11 parts of BS EN ISO 00140 and their subjects. Most parts derive from editions published around 1998, some subsequently revised (years shown are as conveyed by the BS editions).

PartSubjectMeasured object and highlights
BS EN ISO 140-1 (1998/2005)Requirements for laboratory facilities with suppressed flanking transmissionLaboratory acoustic conditions, specimen installation, flanking control
BS EN ISO 140-3 (1995/2005)Laboratory measurement of airborne sound insulation of building elementsDetermination of sound reduction index R of walls, panels
BS EN ISO 140-5 (1998)Field measurement of airborne sound insulation of facade elements and facadesField measurement of windows and curtain walls
BS EN ISO 140-6 (1998)Laboratory measurement of impact sound insulation of floorsFloor insulation under standard tapping-machine excitation
BS EN ISO 140-7 (1998)Field measurement of impact sound insulation of floorsField impact measurement in finished buildings
BS EN ISO 140-8 (1998)Reduction of transmitted impact noise by floor coverings on a heavyweight standard floorImprovement ΔLw of coverings such as carpets
BS EN ISO 140-11 (2005)Reduction of transmitted impact sound by floor coverings on lightweight reference floorsImprovement measured on a lightweight reference floor
BS EN ISO 140-12 (2000)Laboratory measurement of room-to-room airborne and impact sound insulation of an access floorSound insulation of raised access floors
BS EN ISO 140-14 (2004/2009)Guidelines for special situations in the fieldNon-standard rooms, non-uniform elements in the field
BS EN ISO 140-16 (2006)Laboratory measurement of sound reduction index improvement by additional liningsImprovement of added linings (e.g. acoustic ceilings/linings)
BS EN ISO 140-18 (2006)Laboratory measurement of sound generated by rainfall on building elementsIndoor noise levels from rain impact
💡 Impact and airborne sound follow different physical paths: airborne measurement uses the “source–sound-pressure difference” to obtain the sound reduction index R; impact measurement uses standard tapping-machine excitation plus receiving-room level to obtain the normalised impact sound pressure level Ln. Both are measured in 1/3-octave bands (100 Hz–3.15 kHz or wider).

3. Key Technical Requirements 🔥

Key technical requirements across the series include:

  • Source and receiving conditions: airborne measurement uses a diffused-field loudspeaker source ensuring a diffuse field in the source room; multiple receiving positions are averaged to reduce standing-wave effects.
  • Band measurement: insulation is computed in 1/3-octave bands (R(f) or field D values), from which single-number ratings (e.g. Rw, DnT,w per ISO 717) are derived.
  • Flanking control (Part 1): the laboratory must suppress flanking transmission around the specimen so that the measured value is “the element’s own insulation”, not the laboratory structure’s transmission.
  • Tapping machine and floor conditions: Parts 6/7 excite floors with a standard tapping machine (5 hammers, specified spacing and impact force); Parts 8/11 measure covering improvement on standard floors by comparing before/after.
  • Field special situations (Part 14): alternative measurement positions and data processing are given for large non-uniform elements, small rooms and low spaces.
🚨 Field measurements are most easily misled by flanking transmission and background noise: if there are acoustic bridges such as suspended ceiling cavities or service penetrations between adjacent rooms, the measured insulation may be well below the laboratory value. Field reports should record room volume, element size and flanking paths, and apply ISO 717 for single-number rating and correction.

4. Engineering Practice 🛠️

  • 🔍 Element selection and certification: curtain walls, doors and floors are certified in laboratories per ISO 140-3/6; designers use these reports to select element combinations that meet acoustic-code grades.
  • 🔧 Final acceptance: field airborne/impact measurements per ISO 140-4/-7 verify actual building insulation against design targets and regulatory limits.
  • 📊 Floor-covering comparison: use ΔLw from Parts 8/11 to compare carpets, pads and floating-layer solutions and optimise impact-sound control design.
  • 📋 Acoustic retrofit: for rooms over the limit, design ceilings and wall linings using Part 16 improvement data, assessing retrofit effectiveness from measured improvement.

5. Frequently Asked Questions ❓

❓ Q: How do R, field D and the single-number rating Rw relate?
A: R and D are band values (dB, frequency-dependent); single-number ratings such as Rw / DnT,w are derived by fitting a standard reference curve per ISO 717, used for engineering comparison and code setting.
❓ Q: How do ISO 140, ISO 10140 and ISO 16283 relate?
A: ISO 10140 replaces the “laboratory measurement” parts of ISO 140; ISO 16283 replaces the “field measurement” parts. The ISO 140 series (especially the editions around 1998) remains widespread in legacy literature, databases and certification.
❓ Q: Why does the impact improvement ΔLw matter?
A: ΔLw is the decibel reduction of impact sound level after laying a covering — the direct basis for choosing carpets, acoustic pads and floating layers. Since the same covering behaves differently on different floors, it must be measured on the standard floor required by the specification to be comparable.
🔍 Q: Why do field and laboratory insulation values differ?
A: The laboratory excludes flanking and optimises the sound field, measuring “upper-limit” element performance; the field contains flanking paths, acoustic bridges, room size and furniture effects, so measured values are generally lower. Design margin and acceptance criteria should therefore be considered separately.
🔒