BS EN 62442 — Energy Performance of Lamp Controlgear Standard Series

Methods of measurement to determine total input power and efficiency of controlgear circuits (implementing IEC 62442)

💡 BS EN 62442 is the British Standards Institution (BSI) adoption of EN 62442, identical to IEC 62442, covering the energy performance of lamp controlgear. The series is maintained by BSI Technical Committee CPL/34 (Lamps and related equipment) through Subcommittee CPL/34/3 (Auxiliaries for lamps), classified under ICS 29.140.99. Lamp controlgear (commonly known as ballasts/drivers) are the electrical auxiliaries required for the normal operation of fluorescent, high-intensity discharge (HID), halogen and LED light sources, and their energy performance directly determines the energy consumption of the whole lighting system. The series specifies methods of measurement to determine total input power and efficiency for the various classes of controlgear, providing a common technical basis for energy labelling, regulatory compliance and product comparison. The first edition replaced BS EN 50294:1998.

💡 The essence of energy-performance measurement is to quantify “controlgear losses” and “total circuit input power”: the higher the controlgear efficiency and the lower the input power, the more energy-efficient the lighting system — which is precisely why EU lighting energy regulations (e.g. the ErP Directive) reference this series.

1. Scope and Basic Framework 📌

The series was prepared by IEC SC 34C (Auxiliaries for lamps) and comprises three parts, all under ICS 29.140.99, each addressing controlgear for a specific light-source type:

StandardSubjectCorresponding IECKey Content
BS EN 62442-1:2011Fluorescent lamp controlgearIEC 62442-1:2011Method of measurement to determine the total input power of controlgear circuits and the efficiency
BS EN 62442-2:2014HID lamp controlgear (excluding fluorescent)IEC 62442-2:2014Method of measurement to determine the efficiency
BS EN 62442-3:2014Halogen and LED module controlgearIEC 62442-3:2014Method of measurement to determine the efficiency
⚠️ The measurement object is the “controlgear” — the electrical auxiliary that drives the light source, not the light source itself. Measurements are normally made with a specified reference lamp or load connected under rated supply conditions; input power is measured and efficiency calculated. Measurement conditions must strictly follow the standard to ensure comparable results.

2. Series Structure and Technical Points 🔧

2.1 Part 1: Fluorescent lamp controlgear

BS EN 62442-1 applies to fluorescent lamp controlgear (both magnetic and electronic ballasts). The standard gives two measured quantities: the total input power of the controlgear circuit and the efficiency of the controlgear. The method involves connecting the controlgear to a reference fluorescent lamp/equivalent load under specified supply conditions, measuring total input power and calculating efficiency.

2.2 Part 2: High-intensity discharge (HID) lamp controlgear

BS EN 62442-2 applies to controlgear for high-intensity discharge lamps (metal halide, high-pressure sodium, etc., excluding fluorescent). HID controlgear handle larger power and involve complex starting and ignition; the standard specifies the method of measurement to determine their efficiency, including measurement of input and output power under steady-state conditions and efficiency calculation.

2.3 Part 3: Halogen and LED module controlgear

BS EN 62442-3 applies to controlgear for halogen lamps and LED modules (LED drivers). With the widespread adoption of LED lighting, this part specifies efficiency measurement for LED controlgear, providing a methodological basis for the energy-performance evaluation of LED lighting systems.

3. Key Technical Requirements and Measurement Definitions 🔍

The series centres on the following concepts and technical points:

  • Total input power: the total active power absorbed from the mains by the controlgear and its connected load circuit under rated supply conditions, including the controlgear’s own losses.
  • Efficiency: the ratio of output power to total input power, reflecting the energy-conversion capability of the controlgear; the different parts define efficiency for fluorescent, HID and halogen/LED-module controlgear respectively.
  • Measurement conditions: supply voltage, frequency, waveform distortion, ambient temperature and lamp/load type must be set per the specified conditions to ensure comparability across laboratories and products.
  • Reference lamp/equal load: the standard specifies the use of a reference lamp or a defined load to ensure consistency, avoiding the influence of individual lamp variation.
  • Steady state: most measurements are made after the light source reaches steady-state operation, reflecting true long-term running performance.
✅ The engineering value of the series lies in “method harmonisation”: controlgear from different manufacturers measured by the same standard method can be compared directly, and regulators can implement market access and surveillance by energy class.

4. Test Methods and Conformity Assessment 🧪

A typical measurement and evaluation flow includes:

  • Circuit set-up: connect the controlgear to the reference lamp/load per the standard wiring diagram and connect the supply.
  • Input power measurement: measure total input active power at rated voltage/frequency with a calibrated power meter.
  • Output power measurement: measure the power at the lamp/load side (or derive it by a prescribed method) for efficiency calculation.
  • Efficiency calculation: compute the controlgear efficiency per the standard formula.
  • Conditions and reporting: record supply conditions, ambient temperature, reference lamp type and results, and issue a report per the standard format.

The standard itself does not set minimum efficiency limits; it provides the measurement basis for subsequent energy regulations and energy-class ratings.

5. Engineering Practice and Application 🛠️

  • 🔍 Energy labelling and marketing: manufacturers derive energy-performance data by this series for product energy labels and promotion.
  • 🔧 Energy-efficient lighting design: compare the efficiency of different controlgear in engineering design and tendering, selecting high-efficiency products to reduce running electricity cost.
  • 📊 Regulatory compliance: lighting energy regulations in the EU and other markets (e.g. ErP energy requirements) reference this series as the basis for market access and surveillance.
  • 📋 Supply-chain quality control: purchasers and inspection bodies sample-measure controlgear by the standard method to verify the truthfulness of declared energy data.

6. Frequently Asked Questions ❓

❓ Q: What is the relationship between BS EN 62442 and BS EN 50294?
A: BS EN 62442-1 superseded BS EN 50294:1998, bringing fluorescent controlgear energy measurement into the new series; the series further extends to HID controlgear (Part 2) and halogen/LED-module controlgear (Part 3).
❓ Q: Why are both “total input power” and “efficiency” needed?
A: Total input power directly reflects the system’s actual electricity consumption, while efficiency reflects the controlgear’s energy-conversion capability. Together they allow assessment of energy savings and comparison across products of different types and power ratings.
❓ Q: Does the series apply to LED drivers?
A: Yes. Part 3 specifically addresses halogen and LED module controlgear (LED drivers), providing the efficiency measurement method, which is an important basis for current LED lighting energy evaluation.
🔍 Q: Does the standard set minimum efficiency limits?
A: BS EN 62442 itself only specifies measurement methods, not minimum efficiency limits. Minimum limits are set separately by energy regulations (e.g. the ErP Directive) or energy-class systems; the series provides the measurement basis for these regulations.
❓ Q: What factors affect measurement results, and how is comparability ensured?
A: Supply voltage/frequency, waveform, ambient temperature, reference lamp/load type and steady state all affect results. Therefore the conditions and methods specified in the standard must be followed strictly, and all conditions recorded to ensure cross-product, cross-laboratory comparability.
🔒