📡 BS EN 62150 is the British Standard implementation of IEC 62150, forming part of the “Fibre optic active components and devices — Test and measurement procedures” series. It is maintained by BSI Technical Committee GEL/86/3 (Fibre optic systems and active devices), a subcommittee of GEL/86 (Fibre optics). The series specifies test and measurement procedures for active components in fibre-optic communication systems (such as optical transceivers, lasers and detectors), providing a common basis for performance evaluation, incoming inspection and quality assurance. This article covers two parts: Part 2 addresses ATM-PON (Asynchronous Transfer Mode Passive Optical Network) transceivers, and Part 3 addresses the measurement of optical power variation induced by mechanical disturbance at optical receptacles and transceiver interfaces.
💡 The performance of optical network devices (especially optical modules in PON systems) directly determines transmission distance, split ratio and reliability. The BS EN 62150 series standardises test methods so that results from different manufacturers and different laboratories are comparable — it is the foundation for coordinated performance testing from the “component” level up to the “system” level.
1. Overview of the Standard Series 📌
The BS EN 62150 series is maintained by BSI Technical Committee GEL/86/3 (Fibre optic systems and active devices), corresponding to the work of IEC SC 86C (Fibre optic systems and active devices). The series is organised in parts, each addressing a specific class of test object or test scenario. Part 2 (2011 edition) covered here supersedes the 2004 edition; one of the main technical changes relative to the previous edition is that, in the measurement of average optical power (Pave) in clause 7.3.3, the power meter must have a saturation power higher than 2 × Pmean. Part 3 (2015 edition) supersedes the 2012 edition and focuses on the optical power variation caused by mechanical disturbance. As stated in the standard, compliance with a British Standard does not confer immunity from legal obligations, and users remain responsible for correct application.
Within the test framework, the series is used in conjunction with IEC 62150-1 (general methods). Each part supplements the general methods with specific test conditions and acceptance criteria for a particular object, forming a “general + particular” architecture.
2. Structure and Main Parts of the Series 🧩
The BS EN 62150 files covered by this article comprise two parts:
| Standard number | Year | Title | Test object and highlights |
| BS EN 62150-2:2011 | 2011 | Part 2: ATM-PON transceivers | Test and measurement procedures for optical transceiver modules of PON optical network units (ONU) / optical line terminals (OLT), including methods for transmitted optical power, receiver sensitivity and average power |
| BS EN 62150-3:2015 | 2015 | Part 3: Optical power variation induced by mechanical disturbance in optical receptacles and transceiver interfaces | Measuring the optical power variation at optical receptacles and transceiver interfaces under specified mechanical disturbance (insertion, vibration, bending) to assess connection stability |
It is worth noting that ATM-PON (the ITU-T G.983 series) is an early mainstream passive optical network technology, and its transceiver test methods are representative. Although the transceiver testing of the later GPON (ITU-T G.984) and EPON (IEEE 802.3ah) has its own specifications, the underlying test philosophy is consistent with the IEC 62150 series.
3. Key Technical Requirements 🔧
3.1 Part 2: ATM-PON Transceiver Testing
- Transmitter performance measurement: measure transmitted optical power (peak and average), extinction ratio, wavelength and spectral width, eye diagram and jitter, to ensure the transmitted signal satisfies the uplink/downlink power budget of the PON system.
- Receiver performance measurement: measure receiver sensitivity (minimum received optical power at a given bit error ratio, such as 10⁻¹⁰), overload optical power and dynamic range.
- Average power measurement note: in accordance with the relevant clause (for example 7.3.3), the saturation power of the power meter should be higher than 2 × Pmean to avoid distortion of the average optical power measurement.
- Interface and optical characteristics: assess the coupling stability and return loss of the optical interface of the transceiver.
3.2 Part 3: Optical Power Variation under Mechanical Disturbance
At optical receptacles (optical adapters/connector interfaces) and transceiver interfaces, the fibre end face can undergo micro-displacement and gap changes under insertion, bending and vibration, leading to coupling-efficiency fluctuation and optical power variation. Part 3 specifies:
- Method of applying disturbance: the amplitude, frequency and number of cycles of insertion cycles, vibration or bending.
- Optical power monitoring: continuous monitoring of the transmitted optical power during the disturbance, recording the range of variation.
- Acceptance criteria: the pass criterion is that the optical power variation does not exceed a specified threshold, assessing the mechanical stability of the interface.
- Test environment and conditions: specify temperature, humidity, wavelength and input power to ensure repeatable results.
⚠️ Although the optical power variation measurement appears simple, it places high demands on the measurement chain: connector insertion-loss repeatability, fibre-bending loss and source power fluctuation all interfere with the result. Use a highly stable light source and a high-speed sampling power meter, and calibrate the reference channel so that environmental and instrumental factors are separated from the “disturbance under test”.
4. Test Implementation and Data Handling 🧪
Test implementation follows the sequence “condition setting → connection verification → parameter measurement → data recording → result evaluation”. For ATM-PON transceivers, first set the operating mode and bit-error-ratio test configuration required by the standard, then measure the transmitter and receiver parameters in turn. For the mechanical disturbance test, first confirm the initial optical power baseline, then apply the specified disturbance and record synchronously. In data processing, parameters such as average optical power and sensitivity must be calculated according to the definitions and formulas in the standard, taking into account the inherent uncertainty of the test system (connection loss, power meter calibration, etc.).
✅ Practical tip: the series can be used to establish enterprise test specifications for incoming inspection and production-line testing of PON optical modules; for applications sensitive to mechanical stability (such as automotive and industrial field use), the Part 3 disturbance test should be included in environmental reliability qualification.
5. Engineering Practice 🛠️
- 🔍 Selection and verification: when purchasing ONU/OLT optical modules or transceivers, compile acceptance test items based on this series, with emphasis on transmitted optical power, sensitivity and interface stability.
- 🔧 System coordination: the optical power budget of a PON network should be calculated from measured transceiver performance and the losses of fibres and splitters, rather than designed from nominal values which may leave insufficient margin.
- 📊 Reliability management: perform periodic insertion-loss and mechanical-stability checks on connectors and optical-module interfaces, and include them in network operation and maintenance inspections.
- 📋 Documentation and traceability: keep the original test records and evaluation results as evidence for quality traceability and fault investigation.
6. Frequently Asked Questions ❓
❓ Q: How does the BS EN 62150 series relate to the proprietary test specifications of optical-module manufacturers?
A: BS EN 62150 provides standardised, general test methods; manufacturer specifications normally add enterprise-specific parameters and acceptance limits on top of it. During verification, ask the manufacturer to declare which standard clause its test method corresponds to, to improve comparability.
❓ Q: Why does the Pave measurement require a power meter with saturation power higher than 2 × Pmean?
A: ATM-PON upstream signals have a burst characteristic; if the power meter enters saturation near the peak, the average optical power measurement is distorted. This is one of the important technical revisions of the 2011 edition relative to 2004, and should be checked when configuring the test.
❓ Q: For which scenarios is the mechanical disturbance test especially important?
A: It is especially important for scenarios with vibration, frequent insertion, or fibre stress from long-distance routing (industrial sites, automotive, base stations and home wiring). The test can reveal early defects such as contamination of the connector end face and fatigue of the spring.
🔍 Q: Can the Part 2 test be applied directly to GPON/EPON transceivers?
A: ATM-PON belongs to an earlier technology generation; GPON/EPON transceivers should select test items according to their corresponding ITU-T/IEEE specifications and protocol characteristics. However, the measurement principles and methods for transmitter and receiver parameters can be reasonably adapted from the BS EN 62150 series.