๐ BS EN 61800 is the UK adoption of the European standard EN 61800, identical to or based on IEC 61800, commonly known as the Adjustable Speed Electrical Power Drive Systems (PDS) series. It specifies requirements for complete adjustable-speed drive equipment โ comprising a motor, a power conversion unit and a control unit โ covering rating, electromagnetic compatibility (EMC), safety and communication interfaces. It is the core harmonised standard for variable frequency drives (VFDs), servo drives and motion-control products entering the EU and UK markets, and is widely referenced in machinery, HVAC, lifts and pump/fan energy-retrofit applications.
BS EN 61800 follows a “general + specific” architecture: the general parts define terminology, ratings, operating conditions and basic safety of the PDS, while the specific parts address EMC, electrical/thermal/energy safety and communication interfaces. A complete power drive system (PDS) consists of a motor, a power converter (which transforms grid energy into adjustable-speed energy) and a control unit, linked by interfaces and wiring. The standard further distinguishes the Basic Drive Module (BDM) and the Complete Drive Module (CDM) so that equipment at different levels can conform to the relevant clauses separately.
The 12 documents in this batch cover the core volumes. Parts 2, 3 and 5-1 are the generic fundamentals; Part 7 forms the interface and profile specification that connects modern VFDs with fieldbus and industrial Ethernet. Note that BS EN 61800 only governs the drive system itself โ overall machine safety must be addressed together with standards such as BS EN ISO 13849 and BS EN 60204.
The table below lists the parts of BS EN 61800 included in this batch and their subject matter for quick navigation.
| Standard | Subject | Core content |
|---|---|---|
| BS EN 61800-2:2015 | General โ Rating specifications for low-voltage adjustable speed AC PDS | Ratings, operating conditions, load types, electrical & thermal requirements |
| BS EN 61800-3:2004 + A1:2012 | EMC requirements and specific test methods | Emission & immunity limits, test setup, environment 2 |
| BS EN 61800-5-1:2007 | Safety โ Electrical, thermal and energy | Shock hazard, clearances/creepage, thermal & energy hazards |
| BS EN 61800-7-1:2015 | Generic interface & profile โ Interface definition | Generic PDS interface model, parameter sets |
| BS EN 61800-7-201 to 7-204:2016 | Generic interface & profile โ Profiles 1 to 4 | System profiles for drive applications |
| BS EN 61800-7-301 to 7-304:2016 | Generic interface & profile โ Mapping to networks | Mapping to fieldbus/communication networks |
BS EN 61800-2 sets the rating specifications for low-voltage adjustable-speed AC PDS and is the basis for selection and nameplate marking. It defines rated input/output voltage, current, frequency and power, and the operating conditions under continuous, short-time and periodic duty. It clarifies how load types (constant torque, variable torque, constant power) affect ratings, and gives minimum electrical (voltage variation, harmonics) and thermal (cooling, temperature rise) conditions. Engineers must read the rating from the actual load profile rather than rely on the nominal power figure.
BS EN 61800-3 places VFDs inside the EU EMC Directive’s harmonised framework, giving emission and immunity limits โ and dedicated test methods โ separately for Environment 1 (residential/commercial) and Environment 2 (industrial), with test setup, cable length and earthing explicitly affecting results. Because of the inherent high-frequency switching, conducted and radiated emissions are the main compliance challenge; an EMC input filter, shielded motor cable and proper equipotential bonding are typical mitigation measures.
BS EN 61800-5-1 defines basic safety: protection against direct and indirect contact, clearances and creepage distances, insulation coordination, overcurrent/short-circuit protection, thermal hazards (surface temperature limits, over-temperature protection) and energy hazards (braking energy, capacitor discharge). It frames the protection objectives around hazardous voltage, overheating, fire and stored mechanical energy, making it central to CE safety assessment of drive products.
BS EN 61800-7 tackles interoperability between drives and controllers from different vendors: 7-1 establishes the generic interface model and parameter sets (control word, status word, setpoint and feedback), 7-201 to 7-204 define system profiles 1 to 4 (covering generic drives, lifts, cranes, machine tools, etc.), and 7-301 to 7-304 map those profiles onto specific networks (e.g. PROFIBUS, PROFINET, EtherCAT, POWERLINK). This lets a higher-level controller access drives through a consistent parameter semantics.