📡 BS EN 61196 is the British Standard series that adopts EN 61196 (identical to the IEC 61196 series) for coaxial communication cables. It specifies sectional specifications and blank detail specifications for coaxial cables used in communication and signalling, covering flexible coaxial cables and semi-rigid polytetrafluoroethylene (PTFE) dielectric coaxial cables, with requirements for characteristic impedance, attenuation, VSWR and mechanical/environmental performance. Batch BSB053 covers five documents: 61196-10, -10-1, -2, -3-2 and -4.
💡 The “coaxial” structure determines high-frequency performance: the outer conductor shields against electromagnetic interference, the inner conductor carries the signal, and the characteristic impedance is set by the conductor dimensions and the dielectric. The 61196 series standardises impedance, attenuation and uniformity, enabling system-level matching and compatibility.
1. Scope and General Framework 📌
The 61196 series follows the IEC three-tier system of “generic specification – sectional specification – blank detail specification”: the generic specification gives common test methods, sectional specifications give performance requirements by cable type, and blank detail specifications give a template for a single cable type. The documents in this batch include:
- 61196-10 (2016): sectional specification for semi-rigid cables with PTFE dielectric — replaces BS EN 61196-2:2003, specifying the high-frequency electrical, mechanical and environmental requirements of semi-rigid cables.
- 61196-10-1 (2014): blank detail specification for semi-rigid PTFE dielectric cables — a template for the characteristics of a single cable type.
- 61196-2 (2003): sectional specification for communication coaxial cables (scanned).
- 61196-3-2 (1998): blank detail specification for coaxial cables (scanned).
- 61196-4 (2004): sectional specification for coaxial cables (scanned).
⚠️ Documents 61196-2, -3-2 and -4 in this batch are scanned versions, written from public-domain knowledge: Part 2 is the sectional specification for communication coaxial cables (characteristic impedance, attenuation, insulation and sheath), Part 3-2 is a blank detail specification, and Part 4 concerns RF/microwave coaxial cables. The points are summarised from well-established practice; specific values and clauses are governed by the official BSI text.
2. Series Structure and Sub-standard Overview 🗂️
| Standard | Subject | Edition | Core content |
| BS EN 61196-10:2016 | Semi-rigid PTFE dielectric sectional specification | 2016, replaces 61196-2:2003 | Electrical, mechanical and environmental performance of semi-rigid cables |
| BS EN 61196-10-1:2014 | Semi-rigid PTFE blank detail specification | 2014 | Template for individual semi-rigid cable parameters |
| BS EN 61196-2:2003 | Communication coaxial cable sectional specification | 2003 | Requirements and tests for flexible communication coaxial cables (scanned) |
| BS EN 61196-3-2:1998 | Coaxial cable blank detail specification | 1998 | Detail-specification template (scanned) |
| BS EN 61196-4:2004 | RF coaxial cable sectional specification | 2004 | Requirements for RF/microwave coaxial cables (scanned) |
3. Key Technical Requirements 🔧
3.1 Semi-rigid PTFE dielectric coaxial cables (61196-10/-10-1)
Semi-rigid coaxial cables use a solid copper outer conductor and PTFE dielectric, giving low loss, excellent shielding, stable dimensions and the ability to be bent and formed into shape — widely used for instrument and RF module interconnections. Part 10:2016 specifies the characteristic impedance (e.g. 50 Ω), electrical length, attenuation, VSWR and cut-off frequency, plus bending radius, formability, mechanical strength and temperature characteristics; the blank detail specification 61196-10-1 provides a common template for the parameters of each type (outer diameter, impedance, attenuation curves, etc.), with subclause A.2.1.2 revised by the February 2016 corrigendum.
3.2 Communication coaxial cable sectional specifications (61196-2/-4)
Sectional specifications define quality-conformity inspection items and performance limits by cable category: characteristic impedance and impedance uniformity, insertion loss (attenuation), return loss, shielding attenuation, insulation resistance, voltage withstand and mechanical tests (bending, tension, crushing), plus sampling and acceptance requirements, so that manufacturers and users agree on product quality.
3.3 Blank detail specifications (61196-3-2/-10-1)
A blank detail specification is the “template document” of the IEC three-tier system: it lists in tables and clauses all the characteristic parameters to be filled in for a particular cable type (construction dimensions, electrical performance, environmental performance and test conditions). The manufacturer produces the detail specification for that type from the template, ensuring that the specification of the same product type from different manufacturers is consistent and interchangeable for acceptance.
✅ Good coaxial connection design should focus on “impedance continuity”: impedance mismatch between connector, cable and termination causes reflection, raising VSWR and worsening attenuation. Using 61196-specified cables with matched-impedance connectors is the foundation of RF system performance.
4. Engineering Practice and Application 🛠️
- 📡 RF interconnection: use 50 Ω coaxial cable for instruments, base stations and antenna feeders; for long feeder runs, calculate the attenuation budget and VSWR to avoid signal degradation.
- 🛠️ Semi-rigid cable forming: semi-rigid cable can be bent and formed, but the bend radius must not be less than the stated minimum; repeated bending can crack the outer conductor.
- 🔌 Connector termination: strip length, shield handling and crimping quality directly affect reflection and shielding; follow the assembly instructions and sample-test VSWR.
- 🌡️ Temperature considerations: PTFE dielectric withstands high temperature (long-term ~200 °C class), but the mechanical performance of the outer conductor and sheath varies with temperature; observe the temperature rating and mechanical protection during installation and soldering.
- 📋 Acceptance testing: sample-test attenuation, impedance and VSWR on receipt, verify batch reports and detail-specification consistency, and keep test records.
⚠️ Ignoring connector impedance matching is the most common mistake in high-frequency engineering: a connection that “plugs in” but has an impedance discontinuity will reflect at the joint, worsening system VSWR and reducing effective transmitted power — even damaging the transmitter final stage.
5. Frequently Asked Questions ❓
❓ Q: What is the difference between 50 Ω and 75 Ω characteristic impedance?
A: 50 Ω balances power capacity and attenuation and is common for RF and communication equipment; 75 Ω has the lowest attenuation and is common for video and CATV. The two must not be interchanged, as the mismatch causes reflection.
❓ Q: How do I choose between semi-rigid and flexible cable?
A: Semi-rigid cable has lower loss, better shielding and stable dimensions, suited to short, high-performance interconnections (instrument internals); flexible cable bends easily and suits mobile and long-distance routing.
❓ Q: What is the difference between a sectional specification and a blank detail specification?
A: A sectional specification states the requirements and test items for a class of cable; a blank detail specification is the template for the specific parameters of an individual type, forming the “class – type” two-level specification.
❓ Q: What does a high VSWR indicate?
A: It indicates impedance discontinuity and excessive reflection in the transmission path; energy is reflected back to the source, increasing signal attenuation and degrading equipment performance. Check connections and cable damage.
❓ Q: What are the advantages and disadvantages of the PTFE dielectric?
A: PTFE has a small loss tangent, low and stable permittivity, high temperature and chemical resistance, giving semi-rigid cable excellent high-frequency performance; its drawbacks are higher cost and rigidity — not suited to frequent bending.