BS EN 60950 — Information Technology Equipment Safety Standard Series (General Requirements and Large Data Storage Equipment)

Information Technology Equipment — Safety (EN/IEC 60950 Series)

🖥️ BS EN 60950 is the British Standard adopting the IEC 60950 European standard series for safety of information technology equipment (ITE). Developed by IEC/TC 108 (Safety of electronic equipment within the field of audio/video, information technology and communication technology), approved by CENELEC as EN 60950, and adopted in the UK by committee EPL/108, it is one of the most influential safety standards for IT equipment, widely referenced worldwide as the basis for IT safety certification (e.g. CB, CE). This batch includes Part 1 (general requirements, 2006+A2:2013) and Part 23 (large data storage equipment, 2006 edition with 2008 corrigendum).

💡 BS EN 60950-1 establishes the “hazard source — protection” framework for IT equipment safety: comprehensively assessing safety under normal and fault conditions from electric shock, energy, fire, mechanical, thermal, radiation, and chemical perspectives.

1. Scope and General Framework 📌

The BS EN 60950 series applies to information technology equipment, including data processing equipment, office equipment, telecommunication terminal equipment, and their power supply units. The series structure is:

  • Part 1: General requirements: common safety requirements, test methods, and acceptance criteria that all types of ITE must satisfy.
  • Part 23: Large data storage equipment: particular requirements for large data storage equipment, covering storage devices deployed in data-centre environments.

ICS classification is 35.020 / 35.260. BS EN 60950-1:2006+A2:2013 is derived from IEC 60950-1:2005 (incorporating amendment 1:2009 and amendment 2:2013) with CENELEC common modifications; BS EN 60950-23:2006 adopts identically IEC 60950-23:2005 (with October 2008 corrigendum).

⚠️ BS EN 60950-1 is being replaced/transitioned by BS EN 62368-1 (safety of audio/video and ICT equipment, based on hazard-based safety engineering). New designs should assess adopting IEC 62368-1, while existing certifications remain valid during the transition.

2. Series Composition and Technical Points 🔧

StandardTitleFocusIEC EquivalentStatus
BS EN 60950-1:2006+A2:2013General requirementsShock, energy, fire, mechanical, thermal, radiation, chemical safetyIEC 60950-1:2005 (incl. amendments)Current (incl. A2:2013)
BS EN 60950-23:2006Large data storage equipmentParticular requirements for large storage systemsIEC 60950-23:2005Current (incl. 2008 corrigendum)

1. General Requirements (Part 1)

Part 1 covers safety requirements for all types of ITE:

  • Electric shock protection: protection against shock from accessible parts, protective earthing, insulation, and creepage/clearance distances.
  • Energy hazards: protection against burns and arcing from high-current/high-energy circuits.
  • Fire: enclosure flammability ratings (V-class/5V materials), internal fire spread control, and ventilation requirements.
  • Mechanical and thermal hazards: moving-part guarding and hot-surface limits.
  • Radiation and chemicals: control of laser, EMF, and chemical (e.g. battery electrolyte) hazards.

2. Large Data Storage Equipment (Part 23)

Part 23 adds particular requirements for large data storage equipment (e.g. large-scale disk arrays/storage cabinets in data centres), covering the safety aspects of large-capacity storage systems in terms of power supply, cooling, fire protection, and installation environment.

💡 Large data storage equipment operates in data-centre environments where fire and power-supply safety are particularly important: enclosure material, internal cable routing, and coordination with gas-suppression systems are key to data-centre safety design.

3. Key Technical Requirements 🔬

Key technical requirements for IT equipment safety include:

  • Electric shock protection: through basic insulation + protective earthing + supplementary protection, ensure accessible parts are not hazardous to persons under normal and single-fault conditions.
  • Energy hazard control: for high-energy circuits above limits, restrict accessibility and prevent arcing and burns.
  • Fire and enclosure flammability: enclosure materials to V-0/V-1/V-2 flammability ratings, controlling internal fire spread.
  • Temperature and thermal design: accessible surface temperature limits, internal component temperature rise, and heat-dissipation requirements.
  • Structural strength and mechanical protection: enclosure strength, moving-part protection, and stability.
🚨 Common hazards in IT equipment maintenance: hot-plugging power/data cables, opening covers to touch high-voltage circuits, and ESD damaging components. Service de-energised and use anti-static measures; for laser-equipped devices, observe radiation protection.

4. Engineering Practice and Application 🛠️

  • 🔍 Selection and procurement: when procuring servers, network equipment, and storage devices, verify safety certification (e.g. CB/CE/UL) and the applicable safety standard version.
  • 🔧 Installation: install equipment in racks/rooms meeting ventilation, power-supply, and earthing requirements; route cables per fire and heat-dissipation requirements.
  • 📊 Operation monitoring: monitor equipment temperature, fans, and power status; keep the room environment (temperature, humidity, cleanliness) within allowable ranges.
  • 📋 Maintenance and upgrades: de-energise and discharge residual energy before service; restore per manufacturer procedures and perform safety checks afterwards.

5. Frequently Asked Questions ❓

❓ Q: What is the relationship between BS EN 60950-1 and BS EN 62368-1?
A: 62368-1 is the new-generation safety standard for audio/video and ICT equipment based on Hazard-Based Safety Engineering, which will replace 60950-1 and 60065 (audio/video equipment). During transition both coexist; new designs should assess adopting 62368-1.
🖥️ Q: What equipment does Part 23 apply to?
A: Large data storage equipment, i.e. large-scale data storage systems deployed in data centres (e.g. large disk arrays, storage cabinets); its particular requirements supplement power-supply, cooling, and fire-protection considerations.
🔌 Q: Why does IT equipment require protective earthing?
A: Protective earthing diverts fault current to earth, and with the overcurrent protection device quickly disconnects supply, preventing dangerous voltage on accessible metal parts during insulation fault — a key shock-protection measure.
📊 Q: How is IT equipment judged to meet safety requirements?
A: By type testing to the applicable safety standard (e.g. 60950-1 or 62368-1), covering shock, energy, fire, mechanical, thermal, and radiation items; the equipment conforms if all pass and a certificate is issued by a recognised body.
🔒
正在加载下载地址,请稍候 10 秒

Leave a Reply

Your email address will not be published. Required fields are marked *