⚡ BS EN 60871 is the British Standards Institution series adopting European Standard EN 60871, identical to IEC 60871, which covers high-voltage shunt power capacitors for a.c. power systems having a rated voltage above 1000 V, used for reactive power compensation (such as capacitor banks in substations and switching stations). Part 1 specifies general requirements; Part 4 specifies internal fuses. The series was prepared by Technical Committee PEL/33, Power capacitors, and is the basis for the design, testing, safety and operation of high-voltage shunt capacitors.
The BS EN 60871 series is identical to IEC 60871, prepared by IEC/TC 33 “Power capacitors and their applications”, and was adopted in the UK by Technical Committee PEL/33. Part 1 (2014 edition) supersedes the 2005 edition; Part 4 (2014 edition) supersedes the 1997 edition. The series applies to shunt power capacitors with rated voltage above 1000 V at 50 Hz (or 60 Hz), specifying ratings, performance, test methods and safety requirements (Part 1), and the design, testing and protection coordination requirements for internal fuses (Part 4).
| Standard Number | Title | IEC Reference | Main Content |
|---|---|---|---|
| BS EN 60871-1:2014 | Shunt capacitors for a.c. power systems having a rated voltage above 1000 V — Part 1: General | IEC 60871-1:2014 | Ratings, performance requirements, test methods, safety requirements and general provisions |
| BS EN 60871-4:2014 | Shunt capacitors for a.c. power systems having a rated voltage above 1000 V — Part 4: Internal fuses | IEC 60871-4:2014 | Design, electrical performance, test methods and protection coordination requirements for internal fuses |
Part 1 specifies ratings such as rated voltage, rated capacitance, rated frequency, maximum permissible overvoltage, maximum permissible overcurrent, insulation level and temperature category, together with performance requirements such as capacitance tolerance, loss tangent and insulation resistance. High-voltage shunt capacitors are typically composed of multiple internal elements connected in series/parallel; elements are paralleled with internal fuses so that a faulted element is fused and isolated.
Part 1 specifies routine tests and type tests, including: voltage test between terminals, voltage test between terminal and case, capacitance and loss measurement, insulation resistance measurement, internal fuse tests, discharge test, sealing test and temperature-rise test, with test voltage, duration and acceptance criteria.
| Test Item | Property Assessed | Key Parameters | Typical Criterion |
|---|---|---|---|
| Voltage test between terminals | Dielectric withstand capability | Test voltage, duration | No breakdown, no flashover |
| Voltage test terminal-to-case | Insulation to case | Test voltage, duration | No breakdown, no flashover |
| Capacitance and loss measurement | Capacitance and dielectric loss | Capacitance tolerance, loss tangent | Within specified limits |
| Internal fuse tests (Part 4) | Fuse isolation of faulted elements | Fusing current, time, isolation performance | Faulted element reliably isolated; bank continues to operate |
| Destruction test | Fault safety performance | Destruction current, temperature rise | Case does not rupture or eject burning material |
Part 4 specifies requirements for internal fuses of high-voltage shunt capacitors. An internal fuse is connected in series with each internal element (or group of elements); when an element breaks down and short-circuits, the fuse melts under overcurrent, isolating the faulted element from the circuit so that the capacitor continues to operate with a small loss of capacitance, preventing fault escalation. The series specifies fuse structure and materials, electrical performance (fusing characteristics, time-current characteristics), test methods (fusing test, isolation test), and protection coordination requirements (current and energy coordination of the fuse with the element and capacitor bank).
Part 1 includes safety requirements (discharge devices, case earthing, fire and explosion protection, overpressure protection) and an installation/operation guide. Internal fuses and external protection (fuses, relay protection) should be properly coordinated to act correctly under internal faults and external short circuits, ensuring capacitor-bank safety.