BS EN 60793 — Optical Fibres Measurement Methods and Test Procedures Standard Series

Optical fibres — Measurement methods and test procedures (BS EN 60793 series, derived from IEC 60793)

📐 BS EN 60793 is the British national adoption by BSI of EN 60793 (identical to IEC 60793), the family of standards that defines how the dimensional, mechanical, transmission and environmental properties of optical fibres are measured and tested. The series splits into two blocks: Part 1 (Part 1-x) provides the general guidance and individual measurement/test methods — fiber geometry, dimensions, mechanical properties, transmission characteristics and environmental ageing; Part 2 (Part 2-x) specifies the requirements for each fibre category (multimode Class A, single-mode Class B and special fibres), tying the Part 1 methods to concrete product limits. With about 30 documents, the series underpins quality inspection in manufacture, acceptance into operator networks and laboratory calibration.

💡 BS EN 60793-1 and -2 are used together: Part 1 says “how to test”, Part 2 says “what is acceptable”. When specifying fibre, check both the category limits and the method clauses.

1. Scope and Overall Framework 📌

BS EN 60793-1-1 gives the general introduction and guidance for the whole series — organisation of measurement methods, terminology, environmental conditions and reporting, forming the foundation for Part 1. The numbered methods include -1-20 fibre geometry, -1-21 coating geometry, -1-30 to -1-3x mechanical characteristics (tensile proof, bending), -1-40 to -1-4x transmission characteristics (attenuation, cutoff wavelength, mode field diameter, bandwidth) and -1-50 to -1-5x environmental/ageing tests. Each number maps to a single method or family of methods, performed on reel samples, short samples or cabled fibre test lengths.

⚠️ Some older editions (e.g. -1-21:2002, -1-40:2003) are dated, and some files are scanned (READABLE=0) so their text cannot be extracted verbatim. Sections relying on such copies are summarised from public domain knowledge and the latest published version should be consulted.

2. Series Composition and Key Technical Items 🔧

StandardSubjectKey technical content
BS EN 60793-1-1General and guidanceSeries guidance: method organisation, terms, environment, reporting
BS EN 60793-1-20Fibre geometryCladding diameter, core diameter, non-circularity, concentricity error
BS EN 60793-1-21Coating geometryCoating outer diameter, coating-cladding concentricity and non-circularity
BS EN 60793-1-30/31/32/33/34Mechanical characteristicsTensile proof, bending, dimensional mechanical tests
BS EN 60793-1-40/41/42/43/44Transmission characteristicsMode field diameter, attenuation, dispersion, non-linearity
BS EN 60793-1-46/47/48/49Environmental/polarizationEnvironmental and PMD measurement methods
BS EN 60793-1-50/51/52/53/54Environmental testsDamp heat, temperature cycling, high-temperature tests
BS EN 60793-2-10 etc.Product specs (A1/A2/A3)Multimode category specs (A1a/A1b/A1d core/cladding & NA)
BS EN 60793-2-20/30/40/50/60Product specs (B/C/E)Single-mode Class B and special fibre detailed requirements
✅ A clear two-level structure is the hallmark of the 60793 series: Part 1 defines reusable methods, Part 2 defines product categories and limits — the two are maintained independently and referenced together.

3. Key Technical Requirements and Test Items 🔥

For transmission, BS EN 60793-1-40 specifies measurement of mode field diameter (MFD), typically by variable aperture or near-field methods, for single-mode fibre; -1-42 covers attenuation, commonly by the cut-back method for high accuracy; -1-44 covers cutoff wavelength, where bending conditions strongly influence results; -1-41 addresses bandwidth for multimode fibre. Geometrically, -1-20 measures core/cladding geometry and concentricity error by refracted near-field or transverse interferometry, while -1-21 measures coating geometry by shadow or microscopy — both crucial for controlling splice and connector loss.

💡 Test environment and sample condition directly affect results: the standards fix reference temperature, humidity, wrap diameter and relaxation state. When comparing vendor data, confirm both parties cite the same method edition; otherwise the figures are not directly comparable.

4. Engineering Practice 🛠️

  • 🔍 Network acceptance: operators verify in-process and finished fibre against the relevant Part 2 category for attenuation, MFD and cutoff wavelength, recording per the -1-1 report format.
  • 🔧 Manufacturing QC: drawing-line and off-line tests citing -1-20/-1-40 methods feed back into process parameters (preheat temperature, tension).
  • 📊 Failure analysis: mechanical proof testing (-1-30 family) and damp-heat ageing (-1-50 family) assess long-term reliability and hydrogen-induced attenuation risk.
  • 📋 Calibration traceability: labs run proficiency tests against the method clauses to keep measurement uncertainty controlled.

5. Frequently Asked Questions ❓

❓ Q: What do Part 1 and Part 2 each cover?
A: Part 1 is the “method library” defining how each parameter is measured; Part 2 is the “category specification” defining the limits a fibre must meet and which tests apply. Select fibre by Part 2 limits and refer back to Part 1 for method detail.
❓ Q: Why measure mode field diameter instead of core diameter for single-mode fibre?
A: The light field in single-mode fibre extends beyond the physical core, so MFD better governs splice loss and microbend sensitivity — making it the key geometric-optical parameter specified by -1-40.
❓ Q: Why is the cut-back method common for attenuation?
A: It measures output power at the far end, then cuts the sample near the launch end and re-measures input power under the same launch condition; the ratio removes launch-condition effects, giving a highly accurate reference result.
🔍 Q: How is accuracy assured for scanned copies?
A: Some digital copies are scanned images that cannot be extracted verbatim; the related content is summarised from public domain knowledge (marked in the text) and the latest BSI version should prevail for details.
🔒
正在加载下载地址,请稍候 10 秒

Leave a Reply

Your email address will not be published. Required fields are marked *