BS EN 60255 — Measuring Relays and Protection Equipment Standard Series

Measuring relays and protection equipment — the common and function-specific requirements for power-system protection (IEC 60255)
⚠️ This series includes 11 scanned documents. Content for scanned parts is prepared from publicly available domain knowledge; exact values and clauses must be verified against the official BSI publication.

⚡ BS EN 60255 is the UK version of EN 60255 (Measuring relays and protection equipment), identical to the IEC 60255 series, prepared by IEC/TC 95 and adopted as British Standards by Technical Committee PEL/95. The series defines the common technical requirements, electrical and electromagnetic compatibility (EMC) performance, functional characteristic tests and function-specific requirements (overcurrent, distance, frequency, auto-reclosing, pilot protection) of measuring relays and protection equipment used in power-system protection and control. It is the fundamental standards family for development, type testing, grid-connection acceptance and protection setting calculation of protection relays.

💡 Modern protection has evolved from electromechanical relays to digital microprocessor-based protection, yet the common requirements of IEC 60255 (accuracy, insulation, temperature rise, EMC) and functional specifications remain the technical bedrock for “compliant at factory, mutually recognised at grid connection”, and are referenced by newer systems such as IEC 61850.

1. Scope and Field of Application 📌

The EN 60255 series was prepared by IEC/TC 95 with UK participation in Technical Committee PEL/95. It covers various measuring relays and protection equipment used in substations and power plants (overcurrent, earth-fault, distance, directional, frequency, differential, auto-reclosing, etc.) together with their auxiliary and communication interfaces. Part 1 (2010), identical to IEC 60255-1:2009, supersedes the earlier general requirements of BS EN 60255-6 (1995); most Parts were adopted as EN through CENELEC parallel votes and then published as British Standards.

⚠️ Earlier EN 60255 editions (e.g. BS EN 60255-6:1995, BS EN 60255-21-x vibration/shock, BS EN 60255-22-x radiated/EMC) are being gradually replaced by the new IEC 60255 editions and the IEC 61000 series. Confirm whether the Part you cite is current.

2. Series Composition and Technical Scope 🔬

This batch contains 14 documents covering common, power-supply, protection-function and EMC/mechanical-environment Parts:

PartSubject
BS EN 60255-1-2010Common requirements (identical to IEC 60255-1:2009, replaces -6)
BS EN 60255-11-2010Requirements for DC auxiliary power ports (transient and slow variations)
BS EN 60255-121-2014Distance protection function (reach measurement and trip logic)
BS EN 60255-127-2014Over-/under-voltage and frequency protection function
BS EN 60255-149-2013Busbar and bay protection (busbar differential) requirements
BS EN 60255-151-2009Pilot (wire-comparison/directional) protection function
BS EN 60255-21-1-1996Vibration, shock, bump and seismic tests (mechanical env. 1)
BS EN 60255-21-2-1996Bump and shock tests (mechanical env. 2)
BS EN 60255-21-3-1995Seismic tests (mechanical env. 3)
BS EN 60255-22-5-2011Surge (impulse) immunity test (IEC 61000-4-5)
BS EN 60255-24-2001Protection equipment communication protocols (e.g. IEC 60870-5-103)
BS EN 60255-26-2013EMC general requirements and tests
BS EN 60255-27-2014Overcurrent and directional overcurrent protection (incl. IDMT curves)
BS EN 60255-6-1995(Old) common requirements (superseded by -1)

3. Key Technical Requirements 🔥

3.1 Common requirements (Part 1)

EN 60255-1 defines the common technical requirements for protection equipment: ratings, insulation and temperature rise, dielectric performance, accuracy (operating value and operating time), climatic conditions, clearances and creepage distances, contact ratings, and marking and documentation. It supersedes and consolidates the general clauses of the former BS EN 60255-6 and is the basis for the remaining functional Parts.

3.2 Function-specific protection (Parts 27, 121, 127, 149, 151)

  • Overcurrent/directional overcurrent (Part 27): operating characteristics, definite-time and inverse (IDMT) curves, directional discrimination and reclosing coordination.
  • Distance protection (Part 121): reach impedance elements, multi-zone distance and directional characteristics, trip logic and accuracy.
  • Over/under-voltage and frequency (Part 127): thresholds, delays and return characteristics of voltage and frequency protection stages.
  • Busbar protection (Part 149): functional and performance requirements for busbar differential protection.
  • Pilot protection (Part 151): channel and logic requirements for wire-comparison/directional comparison protection.

3.3 EMC and mechanical environment (Parts 22-5, 26, 21-x)

Part 26 defines the EMC general requirements and tests for protection equipment (linking to the IEC 61000-4 series); Part 22-5 defines surge (impulse) immunity; Part 21-x defines vibration, shock, bump and seismic mechanical-environment tests to ensure reliability under the strong electromagnetic and mechanical disturbance of substations.

3.4 Auxiliary supply and communication (Parts 11, 24)

Part 11 defines DC auxiliary power port performance under slow and transient voltage deviations; Part 24 defines the communication protocol of protection equipment (e.g. IEC 60870-5-103) supporting dispatch automation and fault-recording data interchange.

🚨 EMC is the life line of substation protection equipment: transients from switching, lightning and faults intrude through power and signal ports. Surge and EMC immunity tests of Parts 26/22-5 must be completed; otherwise the equipment may maloperate or fail to operate in the field, endangering grid safety.

4. Engineering Practice 🛠️

  • 🔍 Development and type testing: manufacturers carry out insulation, accuracy, EMC and mechanical-environment tests under the series to obtain conformity evidence.
  • 📋 Grid connection and acceptance: utilities use the series as the conformity basis when accepting protection equipment at substations and during refurbishment.
  • 🔧 Setting and operation: protection engineers perform settings based on the operating characteristics and IDMT curves defined in Parts 27, 121, 127, and use them to analyse field operations.
  • 🌐 Dispatch communication: Part 24 protocols enable data interchange between protection devices and dispatch systems for fault location and automation.
💡 Digital microprocessor protection often models per IEC 61850, but its underlying common requirements and EMC are still based on IEC 60255/IEC 61000; for setting calculations always use the IDMT curve family and directional logic actually implemented in the device.

5. Frequently Asked Questions ❓

❓ Q: How do EN 60255 and IEC 60255 relate?
A: BS EN 60255 is identical to the IEC 60255 series; the technical content is the same, and the UK publishes it as EN 60255 for mutual recognition across Europe.
❓ Q: Why are there both -6 and -1?
A: BS EN 60255-6:1995 is the old common-requirements edition, superseded by EN 60255-1:2010 (identical to IEC 60255-1:2009); new designs and assessments should prefer -1.
❓ Q: How reliable are the scanned versions?
A: This series includes scanned files; content has been compiled from public domain knowledge. For specific insulation levels, EMC grades and operating curves, use the current official BSI publication.
🔍 Q: Where are the overcurrent inverse-time (IDMT) curves defined?
A: The operating characteristics of overcurrent/directional overcurrent protection, including IDMT curve types and parameters, are defined in EN 60255-27 and should be the basis for setting calculations.
🔒