BS EN 60252 — AC Motor Capacitors (General Requirements and Motor Start Capacitors)

AC Motor Capacitors — Part 1: General — Performance, Testing and Rating — Safety Requirements — Guidance for Installation and Operation / Part 2: Motor Start Capacitors (IEC 60252 series)

⚡ BS EN 60252 is a CENELEC adoption of the IEC 60252 series, published by BSI as a British Standard, covering AC motor capacitors. AC motor capacitors are widely used for starting and running single-phase induction motors (e.g., refrigerators, air conditioners, washing machines, pumps, fans, compressors): the capacitor phase shift produces a rotating magnetic field that helps the motor start or improves power factor. The ICS classifications are 31.060.30 and 31.060.70, handled by BSI technical committee PEL/33 (Power capacitors). The series comprises Part 1 (general requirements) and Part 2 (motor start capacitors).

💡 A single-phase motor cannot generate a rotating magnetic field by itself and must rely on a start/run capacitor for phase shift: without the right capacitor, the motor may fail to start, start weakly, or run with degraded performance. Capacitor selection and matching directly determine the reliable operation of single-phase motors.

1. Series Overview and Scope 📌

The BS EN 60252 series applies to capacitors for motors with rated voltage not exceeding a specified value (typically low-voltage AC), including run capacitors and start capacitors. Part 1 gives general requirements (performance, testing, rating, safety and installation/operation guidance); Part 2 gives specific requirements for motor start capacitors.

  • BS EN 60252-1:2011+A1:2013: Part 1, General — Performance, testing and rating — Safety requirements — Guidance for installation and operation, identical to IEC 60252-1:2010. It supersedes BS EN 60252-1:2011, approved by CENELEC on 2011-01-02.
  • BS EN 60252-2:2011+A1:2013: Part 2, Motor start capacitors, identical to IEC 60252-2:2010 (incorporating amendment 1:2013). It supersedes BS EN 60252-2:2011, approved by CENELEC on 2011-01-19.
⚠️ Start capacitors and run capacitors serve different purposes: the start capacitor is energised only during the start transient (short-duration high current), while the run capacitor is connected continuously. Their ratings, voltage withstand and life requirements differ and they are not interchangeable.

2. Series Composition and Technical Points 📋

PartTitleMain Technical Content
BS EN 60252-1:2011+A1:2013General requirementsPerformance, testing and rating; safety requirements; installation and operation guidance (applicable to all motor capacitors)
BS EN 60252-2:2011+A1:2013Motor start capacitorsRatings, tests, safety and destruction test requirements for start capacitors (including definition of segmented film capacitors)

Part 1 establishes the general framework and installation/operation guidance, while Part 2 specifies requirements for the short-duration high-current, frequent switching and destruction safety of start capacitors. The Part 2 revision clarifies the definition of “segmented film capacitors” and the purpose of d.c. conditioning in the destruction test.

3. Key Technical Requirements 🔧

The technical requirements of the BS EN 60252 series include:

  • Rated parameters: rated voltage, rated capacitance, rated frequency, climatic category and temperature range, as the basis of selection and testing.
  • Performance and tests: test methods and acceptance criteria for capacitance tolerance, dissipation factor, insulation resistance, voltage withstand and endurance.
  • Safety requirements: requirements for enclosure, terminals, shock protection and fire safety, as well as safe failure modes of the capacitor (e.g., destruction tests, segmented film design).
  • Installation and operation guidance: mounting method, connection, discharge requirements and operating environment limits, guiding correct use.
  • Start capacitor specific requirements (Part 2): short-time duty, switching cycles and destruction test requirements for start capacitors, ensuring safety under frequent starting duty.
🚨 Capacitor failure is a common cause of appliance and small-equipment faults: as a capacitor ages, its capacitance drops, causing weak motor starting, overheating and even burnout. Allow sufficient margin in selection and pay attention to voltage and temperature ratings.

4. Engineering Practice 🛠️

In the appliance, HVAC, pump and small motor industries, the BS EN 60252 series is the basis for capacitor selection, inspection and replacement:

  • 🔍 Motor matching: choose run/start capacitors with appropriate capacitance, voltage withstand and duty based on motor power, starting method and operating conditions.
  • 🔧 Repair and replacement: verify rated parameters and terminal connections when replacing, avoiding using the wrong type (start/run).
  • 📊 Quality inspection: perform capacitance, voltage and endurance tests per Parts 1 and 2 to support incoming inspection.
  • 📋 Safety assessment: evaluate the safe failure modes and installation environment of capacitors to prevent overheating, bursting and electric shock risks.

5. Frequently Asked Questions ❓

❓ Q: What is the difference between run and start capacitors?
A: A run capacitor stays connected continuously, helping the single-phase motor maintain the rotating field during normal operation; a start capacitor is energised only at start-up, providing high torque to help the motor start, and is removed afterwards. Their duty and life requirements differ.
❓ Q: Why do capacitors age and fail?
A: Under temperature, voltage and ripple stress, the dielectric of organic-film capacitors gradually degrades: capacitance drops, losses rise, and finally the capacitor fails. Selection should account for temperature and voltage margin, and heat dissipation.
❓ Q: What is the purpose of the “segmented film” design?
A: Segmented film capacitors have segmentation structures on the film that automatically isolate fault points on local breakdown, reducing the risk of bursting and fire of the whole capacitor and improving safety — a key focus of the destruction test.
🔍 Q: What parameters should be checked when replacing a capacitor?
A: Verify rated voltage (not less than the original), capacitance (matched to the motor), frequency, duty (start/run), climatic category and terminal connections; consult the motor nameplate or standard where necessary.
🔒