BS EN 60243 — Electric Strength of Insulating Materials Test Methods

Electric strength of insulating materials — Test methods (power frequencies, direct voltage and 1,2/50 µs impulse)

⚡ BS EN 60243 is the British Standards Institution (BSI) implementation of the European Standard EN 60243 (derived from IEC 60243) covering test methods for the electric strength of insulating materials. Electric strength is one of the most important electrical performance indicators of solid insulating materials, characterising their resistance to breakdown under an electric field and directly influencing the design insulation level and safety margin of electrical equipment. This series systematically specifies test methods under three typical voltage forms: power frequency, direct voltage, and 1,2/50 µs lightning impulse. It is the common basis for design, material selection and quality inspection of motors, transformers, cables, capacitors and electrical insulation components. The UK participation is entrusted to Technical Committee GEL/112 (Evaluation and qualification of electrical insulating materials and systems); ICS is 17.220.99 and 29.035.01.

💡 Electric strength is not an inherent material constant — it depends on specimen thickness, voltage form, rate of rise, electrode shape and environmental conditions. A unified, standardised test method is therefore the prerequisite for comparability and repeatability.

1. Series Overview and Scope 📌

The British Standards in this batch cover three parts, each addressing a different voltage form:

StandardPart ContentCorresponding IEC
BS EN 60243-1:2013Part 1: Tests at power frequenciesIEC 60243-1:2013
BS EN 60243-2:2014Part 2: Additional requirements for tests using direct voltageIEC 60243-2:2013
BS EN 60243-3:2014Part 3: Additional requirements for 1,2/50 µs impulse testsIEC 60243-3:2013

Part 1 is the general basis; Parts 2 and 3 add special requirements for direct voltage and impulse voltage respectively, used in conjunction with Part 1. Each part supersedes its earlier edition (e.g., BS EN 60243-1:1998, BS EN 60243-2:2001, BS EN 60243-3:2002).

⚠️ Electric strength testing is a destructive high-voltage test; specimens may break down, flash over or even burn. The test must be performed on high-voltage apparatus with safety shielding, earthing and interlocks, in strict compliance with safety procedures.

2. Test Principle and Terminology 📐

In an electric strength (dielectric strength) test, the specimen is placed between two electrodes and the voltage is raised according to the specified form and rate until breakdown occurs; the voltage at that instant is recorded. The ratio of breakdown voltage to specimen thickness is the electric strength (kV/mm).

  • Breakdown: the medium between electrodes loses its insulating properties under the field, forming a conductive channel;
  • Flashover: discharge along the specimen surface or edge, which may cause a low reading;
  • Partial discharge: local micro-discharges that may precede breakdown and must be distinguished from total breakdown.

The standard defines several electrode configurations (plane, spherical, cylindrical, etc.) and specimen conditions (thickness, pre-treatment), with different electrode/specimen combinations used to assess performance under different field distributions.

3. Power-Frequency Test Method (Part 1) 🔌

BS EN 60243-1 is the basis of the series and specifies tests at power frequency (typically 50 Hz or 60 Hz):

  • Electrode systems: typical configurations such as plane–plane, sphere–plane, cylinder–plane, with corresponding specimen sizes;
  • Voltage rise: continuous or stepwise rise, with commonly used rates of rise;
  • Specimen preparation: thickness, shape, and pre-treatment (e.g., drying, water immersion, temperature conditioning);
  • Result handling: calculation of breakdown voltage and electric strength, and statistical treatment (e.g., median or mean).
💡 The power-frequency test is the closest method to actual a.c. service. Because dielectric-loss heating is significant at power frequency, results are usually lower than under d.c. or impulse — so a.c. insulation design is generally based on power-frequency strength with a safety margin.

4. Direct-Voltage and Impulse Additional Requirements (Parts 2 and 3) ⚡

Parts 2 and 3 add provisions for the special phenomena under d.c. and impulse voltage:

  • Direct-voltage test (Part 2): accounts for space-charge effects, polarity effects and dielectric absorption under d.c. fields, specifying the d.c. voltage-rise programme, polarity selection and measurement requirements;
  • 1,2/50 µs impulse test (Part 3): uses the standard lightning impulse waveform (1.2 µs front time, 50 µs time-to-half-value), specifying impulse generators, waveform verification, number of impulses and polarity — used to assess the ability of insulation to withstand transient overvoltages.

Impulse testing simulates the effect of lightning or switching overvoltages on insulation and is especially important for high-voltage and outdoor equipment. The standard specifies tolerances on the impulse waveform, the measuring system and the acceptance criteria.

🚨 In high-voltage testing, avoid misjudging “edge flashover as breakdown”. Specimen thickness and electrode dimensions should be such that breakdown occurs inside the specimen rather than as surface flashover; if flashover occurs, adjust the electrode configuration or enlarge the specimen and retest.

5. Test Control and Engineering Application 🛠️

  • 🔍 Specimen conditioning: strictly follow thickness measurement, pre-treatment and environmental control — moisture content significantly affects results.
  • 🔧 Apparatus verification: high-voltage apparatus, dividers and measuring systems should be periodically verified to ensure voltage measurement accuracy.
  • 📊 Statistics: electric strength data are scattered; test the prescribed number of specimens and evaluate with appropriate statistics (e.g., median, Weibull analysis).
  • 📋 Material application: slot insulation, transformer turn insulation and cable insulation all use electric strength as a key selection indicator, combined with thermal, mechanical and environmental ageing performance.

6. Frequently Asked Questions ❓

❓ Q: What is the relationship between the three parts of BS EN 60243?
A: Part 1 is the general power-frequency basis; Parts 2 and 3 give additional requirements for direct voltage and 1,2/50 µs impulse respectively, used together with Part 1.
❓ Q: Is electric strength a material constant?
A: No. It varies with specimen thickness, voltage form, rate of rise, electrode shape, temperature and humidity, so it must be measured by the standard method and the test conditions reported.
❓ Q: Why are power-frequency results usually lower than d.c.?
A: At power frequency, dielectric-loss heating and field-distribution effects are more pronounced, favouring thermal breakdown, so the measured power-frequency strength is usually lower than under d.c. or impulse.
🔍 Q: What service condition does the impulse test simulate?
A: It simulates transient overvoltages such as lightning and switching overvoltages, using the standard 1,2/50 µs lightning impulse, to assess the ability of insulation to withstand them without breakdown.
❓ Q: How do I distinguish breakdown from flashover in a test?
A: Breakdown occurs inside the specimen, typically with a sudden voltage collapse and current surge; flashover occurs on the surface or edge, often due to field concentration. Enlarge the specimen or adjust electrodes to avoid flashover interference.
🔒