🔌 BS EN 50289 is the UK implementation of CENELEC EN 50289, “Communication cables — Specifications for test methods”, mirrored by BSI Technical Committee EPL/46 (Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling). Organised in three families — 1-x electrical, 3-x mechanical, and 4-x environmental and fire test methods — the series standardises, item by item, the test procedures for communication cables (data, coaxial, instrumentation cable). It works side by side with cable product standards such as EN 50288 and is the unified basis for factory assessment and acceptance of LAN cabling (Cat.5e/6/6A), industrial Ethernet and transmission-network cables.
📌 Note: of the 18 documents in the series, most are scanned copies. Where specific frequency ranges, limits and procedural details are discussed, the text is based on public-domain knowledge and marked “扫描版本,依据公开领域知识撰写” (scanned version, written from public-domain knowledge); the authoritative requirements must be taken from the official BSI publication.
Electrical performance (impedance, crosstalk, attenuation), mechanical integrity (tension, bending, crushing) and environmental tolerance (temperature, flame, smoke, corrosive gases) together decide whether a communication cable can carry high-frequency signals reliably for years. EN 50289 standardises these tests one by one: electrical parts (1-x) measure transmission characteristics; mechanical parts (3-x) verify resistance to damage during installation and use; environmental parts (4-x) verify fire safety and weathering. The series began publication in 2001 and has been progressively revised (e.g. Part 1-1:2017, Part 4-16:2016, Part 4-17:2015), aligned with fire-safety requirements under the EU Construction Products Regulation.
The scope covers all types of communication cables — twisted-pair data cable, coaxial cable, multi-core control and signal cables. Test results support product-standard conformity assessment, CE marking and acceptance.
The table below lists the main parts of EN 50289 (grouped by category) with Chinese subject descriptions.
| Part | Subject | Typical edition |
|---|---|---|
| EN 50289-1-1 | Electrical test methods — general requirements | 2017 |
| EN 50289-1-8 | Electrical test methods — capacitance | 2017 |
| EN 50289-1-9 | Electrical test methods — crosstalk attenuation (NEXT/FEXT) | 2017 |
| EN 50289-1-11 | Electrical test methods — characteristic impedance, input impedance, return loss | 2016 |
| EN 50289-1-17 | Electrical test methods — exogenous crosstalk ExNEXT and ExFEXT | 2015 |
| EN 50289-3-6 | Mechanical test methods — tensile performance | 2001 |
| EN 50289-3-8 | Mechanical test methods — impact | 2013 |
| EN 50289-3-11 | Mechanical test methods — repeated bending | 2001 |
| EN 50289-3-12 | Mechanical test methods — crushing | 2001 |
| EN 50289-3-13 | Mechanical test methods — torsion | 2003 |
| EN 50289-3-16 | Mechanical test methods — abrasion | 2001 |
| EN 50289-3-17 | Mechanical test methods — creep | 2002 |
| EN 50289-4-5 | Environmental test methods — temperature cycling | 2008 |
| EN 50289-4-7 | Environmental test methods — water immersion/humidity | 2008 |
| EN 50289-4-12 | Environmental test methods — flame propagation (vertical bunched) | 2004 |
| EN 50289-4-14 | Environmental test methods — smoke density | 2003 |
| EN 50289-4-16 | Environmental test methods — halogens (corrosive gas emission) | 2016 |
| EN 50289-4-17 | Environmental test methods — toxicity index | 2015 |
General requirements (1-1). Prescribes environmental conditions (temperature, humidity, pressure), specimen length and termination, and equipment calibration — the precondition of every electrical test.
Impedance and return loss (1-11). Measures characteristic impedance, input impedance and return loss over the defined frequency range to verify impedance matching between cable and connection system — the core high-frequency indicator for data cables.
Crosstalk (1-9, 1-17). Part 1-9 measures near-end (NEXT) and far-end (FEXT) crosstalk attenuation between pairs; Part 1-17 addresses “exogenous crosstalk” (ExNEXT/ExFEXT) — interference from adjacent cables or bundles onto a target circuit — critical for Cat.6A and above in dense deployments.
Mechanical tests (3-x). Tension, repeated bending, crushing, torsion, abrasion and creep simulate pulling, dragging, clamping and long-term loading in service, verifying sheath and core structure strength.
Environmental and fire tests (4-x). Temperature cycling and humidity verify weathering; flame propagation, smoke density, halogen emission and toxicity index evaluate fire safety and corrosive hazard — mandatory criteria for risers and telecom rooms.