🏭 BS EN 16497 is a European standard developed by CEN for building chimneys. It specifies the technical requirements for concrete system chimneys. The series comprises two parts: EN 16497-1:2015 covers non-balanced flue applications (where combustion air is taken from the installation room), and EN 16497-2:2017 covers balanced flue applications (sealed combustion where combustion air is drawn from outside and flue gas is discharged through the same system). Published in the UK by BSI (British Standards Institution) with ICS 91.060.40 (Chimneys and ducts) and UK technical responsibility under committee B/506 (Chimneys), the series is an important technical basis for the design, manufacture, installation, and acceptance of concrete system chimneys, widely used for flue systems of gas/oil boilers and water heaters in residential and commercial buildings.
💡 Concrete system chimneys consist of prefabricated concrete sections, liners, and connectors, offering fire resistance, durability, and fast installation. “Non-balanced” means combustion air is taken from the installation space (room-sealed but not balanced); “balanced” means combustion air is drawn from outside and flows in and out in balance within the same system (sealed combustion). The two place different demands on chimney construction.
1. Scope and General Framework 📌
This series applies to concrete system chimneys and their components. It is structured in two parts:
| Standard | Title | Core Content |
| BS EN 16497-1:2015 | Non-balanced flue applications | Form, materials, structure, and performance requirements for concrete system chimneys in non-balanced (room-air) applications |
| BS EN 16497-2:2017 | Balanced flue applications | Form, materials, structure, and performance requirements for concrete system chimneys in balanced flue (outside-air) applications |
BS EN 16497-1 was prepared by the CEN working group B/506/4 (Chimneys and their components having inner linings of concrete); BS EN 16497-2 by B/506 (Chimneys). Part 1 was published in February 2015 and Part 2 in March 2017, both with ICS 91.060.40.
⚠️ The distinction between non-balanced and balanced applications is critical: in a non-balanced system combustion air comes from the room and the chimney carries flue gas under positive pressure combined with room negative pressure; in a balanced (sealed) system combustion air comes from outside and gas and air flow in balance within the same system. Select the corresponding part according to the appliance combustion method to avoid flue-gas spillage and carbon-monoxide risk.
2. Series Structure and Main Technical Content 🔧
The core technical content of this series includes:
- Form: section types, liner structure, connection methods, and associated components of concrete system chimneys.
- Materials: performance requirements for concrete, liner materials, and connectors, including resistance to flue condensate corrosion, temperature, and fire.
- Structural requirements: structural performance such as section strength, gastightness, and thermal (insulation) performance, with test methods.
- Installation and connection: assembly, sealing, and interface requirements so flue gas is reliably discharged.
💡 Concrete chimney liners typically use acid-resistant concrete or corrosion-resistant liners to resist attack by acidic flue condensate. Liner corrosion resistance and overall gastightness are key to long-term safe operation.
3. Key Technical Requirements 🔥
Key technical requirements for concrete system chimneys include:
| Performance Category | Typical Requirements | Remarks |
| Temperature performance | Safe operation at the specified flue-gas temperature | Temperature class determines applicable heat-source types |
| Corrosion resistance | Liner resists flue condensate corrosion | Ensures long service life |
| Gastightness | Joints and body sealed reliably, no flue-gas leakage | Prevents spillage and safety risks |
| Structural strength | Sections meet strength and stability requirements | Carries self-weight, wind, and thermal loads |
| Thermal insulation | Meets the corresponding insulation class | Controls surface temperature and condensation |
🚨 If a chimney system is not gastight or its liner fails by corrosion, flue gas (including carbon monoxide) can leak into the building, creating severe safety hazards. Concrete system chimneys must be designed, type-tested, installed, and accepted strictly per the standard, with periodic inspection of liners and joints.
4. Engineering Practice and Application 🛠️
- 🔍 Selection and design: select the corresponding part of the concrete system chimney based on the heat-source appliance type (gas/oil boiler, water heater) and combustion method (non-balanced/balanced), verifying temperature and insulation classes.
- 🔧 Installation: assemble sections, seal, and support per the manufacturer’s instructions and standard requirements, maintaining chimney verticality and flue cross-section.
- 📊 Acceptance: after installation, perform gastightness checks and combustion tests to verify proper flue-gas discharge without spillage.
- 📋 Operation and maintenance: periodically inspect liners, joints, and outlet condition; remove soot and condensate; repair corrosion and leaks promptly.
5. Frequently Asked Questions ❓
❓ Q: What is the difference between non-balanced and balanced flues?
A: In a non-balanced system combustion air comes from the room and the chimney only discharges flue gas; in a balanced (sealed) system combustion air comes from outside and air and flue gas flow in balance within the same system. Each must be paired with the corresponding appliance.
❓ Q: What is the relationship between BS EN 16497-1 and BS EN 16497-2?
A: They are two parts of the same series, specifying concrete system chimney requirements for non-balanced and balanced flue applications respectively. Select the part by the appliance combustion method.
❓ Q: Why is the concrete chimney liner important?
A: The liner must resist corrosion by acidic flue condensate to ensure long-term safe operation; liner failure accelerates structural deterioration and can cause flue-gas leakage.
❓ Q: Can concrete system chimneys be used with all fuels?
A: Select a chimney with the appropriate temperature and corrosion-resistance class according to the appliance fuel type (gas, oil, etc.), flue-gas temperature, and condensing characteristics, and verify against the standard scope.
❓ Q: How is installation quality ensured?
A: Assemble, seal, and support per the manufacturer’s instructions and standard requirements; perform gastightness checks and operational tests after installation; maintain and inspect liners and joints periodically.