⚙️ BS EN 15714 is the European standard series for actuators on industrial valves, prepared by CEN/TC 69 and published by BSI with input from Technical Committee PSE/18/5 (valve actuators). It provides a unified terminology and basic requirements for electric, pneumatic and hydraulic valve actuators, covering classification, designation, interface connection, performance requirements and verification tests. It is the common technical basis for communication and acceptance among actuator manufacturers, valve packagers and end users.
💡 The actuator is the “power heart” that converts a control signal into mechanical valve-stem motion: drive type (electric/pneumatic/hydraulic), travel type (part-turn/multi-turn/linear) and fail-safe arrangement together determine the selection logic.
1. Scope and General Framework 📌
The BS EN 15714 series applies to actuators installed on industrial valves, including electric, pneumatic and hydraulic actuators. It covers terminology and definitions, basic requirements, performance parameters and test methods, ensuring compatibility and safe, reliable operation with the valve and control system. The standard does not replace specific explosion-protection or enclosure requirements, which should be addressed under the applicable electrical and hazardous-area standards.
⚠️ BS EN 15714 gives “basic requirements” for actuators; additional requirements for specific applications (petrochemical, power, water treatment) such as explosion protection, corrosion resistance and EMC must follow project specifications and other applicable standards (e.g. the ATEX and IEC explosion-protection series).
2. Structure of the Series and Technical Essentials 🔧
The BS EN 15714 series comprises four parts:
| Standard | Title | Status | Core Content |
| BS EN 15714-1:2009 | Part 1: Terminology and definitions | 2009 | Common terms for electric, pneumatic and hydraulic actuators and category-specific terms |
| BS EN 15714-2:2009 | Part 2: Electric actuators for industrial valves — basic requirements | 2009 | Classification, designation, performance and test requirements for electric actuators |
| BS EN 15714-3:2009 | Part 3: Pneumatic part-turn actuators — basic requirements | 2009 | Classification and requirements for pneumatic part-turn (rack-and-pinion/scotch-yoke) actuators |
| BS EN 15714-4:2009 | Part 4: Hydraulic actuators — basic requirements (scan) | 2009 | Classification, designation and basic requirements for hydraulic actuators |
💡 Part 1 establishes the terminology used throughout the series: the three travel types — part-turn, multi-turn and linear — are the core classification dimension, and their definitions determine the applicability of the subsequent parts.
3. Key Technical Requirements 🛠️
As seen in the text of Parts 2 and 3, the BS EN 15714 series sets out the following key technical requirements:
- 📐 Classification and designation: by drive type (electric/pneumatic/hydraulic), travel type (part-turn/multi-turn/linear) and output performance (torque, thrust, travel), with a clear designation method.
- 🔌 Interface and mounting connection: dimensions and tolerances of the connection between actuator and valve (e.g. ISO 5211 flange interface, valve-stem drive connection) to ensure interchangeability.
- ⚡ Performance parameters: definition of rated output torque/thrust, travel time, control-signal type (on-off/modulating), fail position (fail-safe) and their measurement methods.
- 🧪 Test requirements: no-load and loaded operation tests, travel and limit tests, sealing and protection tests, endurance tests, etc.
- 📋 Marking and documentation: requirements for nameplate information, instruction manuals and technical documents to ensure traceability and correct installation and use.
🚨 The most important selection step is “torque/thrust sizing”: the actuator’s rated output must exceed the valve’s opening/closing torque under the worst conditions (maximum differential pressure, seat friction, medium-temperature variation) with a safety factor, otherwise the valve will fail to operate or the motor will overload.
4. Technical Characteristics by Type 🧪
The three actuator types have different characteristics; choose according to process and control requirements:
- ⚡ Electric (Part 2): high output torque, good control accuracy, easy remote and intelligent control; suited to large valves and unattended sites; consider supply, explosion protection and fail position on loss of power.
- 💨 Pneumatic part-turn (Part 3): simple construction, fast operation, easy air-to-open/air-to-close and fail-in-place on loss of air; widely used on ball and butterfly valves; requires an air-treatment unit.
- 💧 Hydraulic (Part 4): high output force, smooth motion, long holding capability; suited to very large, high-differential-pressure valves and applications needing sustained thrust; more complex system and higher maintenance.
5. Engineering Practice and Application 🏗️
Practical applications of the BS EN 15714 series include:
- 🔍 Selection and procurement: standardise actuator technical specifications using the standard’s classification and designation methods, unifying tender and acceptance language.
- 🔗 Valve–actuator packaging: use the interface standard to achieve interchangeability and matching between actuators and valves from different manufacturers.
- 📋 Testing and acceptance: complete factory tests and site acceptance according to the standard’s test methods, ensuring performance compliance.
- 🛠️ Operation and maintenance: build an O&M documentation system using the standard’s terminology, and standardise inspection and troubleshooting.
✅ Practice essentials: after fixing drive and travel types, size the torque/thrust, then determine control-signal and fail-safe requirements, and finally check interface dimensions and protection class to form a complete actuator specification.
6. Frequently Asked Questions ❓
❓ Q: What actuator types does BS EN 15714 cover?
A: Electric, pneumatic and hydraulic actuators for industrial valves. Part 2 covers electric actuators, Part 3 pneumatic part-turn actuators, and Part 4 hydraulic actuators.
❓ Q: What is the difference between part-turn, multi-turn and linear actuators?
A: Part-turn outputs a partial rotation (e.g. 90°) for ball and butterfly valves; multi-turn outputs multiple rotations for gate and globe valves; linear outputs a linear displacement for linear control valves.
❓ Q: Why must torque be sized before selecting an actuator?
A: The actuator’s rated output must cover the valve’s opening/closing torque under the worst conditions with margin, otherwise reliable operation fails. Obtain the valve torque-vs-travel curve and check against the medium conditions.
❓ Q: Is explosion protection included in BS EN 15714?
A: No. BS EN 15714 gives basic mechanical/electrical requirements; actuators in hazardous areas must also meet the applicable explosion-protection standards (e.g. ATEX and the IEC explosion-protection series).
📄 Q: Why is Part 4 flagged as a “scan”?
A: In this source set BS EN 15714-4:2009 is a scanned version with limited text readability; related technical content is written from public-domain knowledge, and the official BSI published version takes precedence.